1. WALL MOUNT INSTALLATION
a.
Make sure all preparation steps are completed.
b.
Determine your ceiling height to verify if you will require an extension.
ii. Duct cover height = 17-3/4" (lower) + 17-3/4" (upper w/ luvers)
iii. Minimum height (duct cover only)= 17-3/4"
iv. Maximum height (duct cover only) = 35"
v. (OPTIONAL) Extension duct cover height = 39-1/2‖
vi. Maximum height (duct cover with extension only) = 56"
c.
Determine the location you want to install the range hood.(Fig. 2a)
d.
Mount the unit onto the wall with provided toggle bolt anchors.
e.
Adjust the duct cover mounting bracket to your desired height.
f.
Use a spirit level to ensure the unit is leveled.
Connect the 7‖ exhaust piping to the outlet collar of the unit. (Fig. 2b)
g.
h.
Finish off by sealing the connection point with aluminum tape (Be sure it
is secure with no opening or gaps).
i.
Slide the duct cover into the unit and adjust its height. (Fig. 2c)
j.
Secure the duct cover with the screws provided. (Fig. 2d)
2. EXTENSION DUCT COVER INSTALLATION
**EXTENSION MAY REQUIRE MODIFICATION**
Windster Hood will not be responsible for any modification done.
a.
Replace the original upper duct cover piece with the extension.
Determine the desired height (up to 10' ceiling) to mount the duct cover.
b.
REPEAT STEP F – M of Section 1 WALL MOUNT INSTALLATION
c.
section.