Page 1
User’s Manual RH-W30SS RH-W36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed for indoor residential use only. DO NOT USE OVER A WOOD GRILL OR MOUNT...
SAFETY INFORMATION SAFETY INFORMATION TO REDUCE THE RISK OF A FIRE, ELECTRICAL SHOCK, AND/OR INJURY OBSERVE THE FOLLOWING: Unit is intended for indoor residential use only. If you should have questions, contact the manufacturer at the address or telephone number listed in the warranty.
SAFETY INFORMATION TO REDUCE THE RISK OF FIRE, OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE. Regardless of heat level, never leave any surface materials unattended while operating an open flame. Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
PREPARATION PREPARATION BEFORE YOU START **BE SURE YOUR UNIT WILL FIT YOUR CEILING HEIGHT** **DO NOT INSTALL IF DAMAGED** **RETURN OR EXCHANGE WILL BE DENIED IF INSTALLED** Be sure you have all the content of your purchase and required tools for this installation.
2. EXTENSION DUCT COVER INSTALLATION EXTENSION MAY REQUIRE MODIFICATION Windster Hood will not be responsible for any modification done. Replace the original upper duct cover piece with the extension. Determine the desired height (up to 10’ ceiling) to mount the duct cover.
INSTALLATION 3. COLD WEATHER INSTALLATION (OPTIONAL) Check with your local building codes to see if a CFM reducer is an acceptable alternative to make-up air. Remove the RH-WCFMR (CFM Reducer) and inspect for any sign of defect or damage. (ie. Cracks, broken flips) AFTER COMPLETING Step A –...
OPERATION & FEATURES OPERATION & FEATURES EASY ACCESS CONTROL SWITCH (from left to right) Button 1 – Power ON / OFF Button 2 –Low Speed Button 3 –Medium Speed Button 4 – High Speed Button 5 – Light Switch ALUMINUM FILTERS (2) 14-1/2‖...
CLEANING & MAINTENANCE CLEANING& MAINTENANCE WARNING!!! To prevent the possibility of a fire and explosion, do not use flammable liquids or solvents to clean the unit or any of its parts. Check to make sure all power sources are disconnected before servicing or taking unit apart for cleaning.
TROUBLESHOOTING TROUBLESHOOTING WARNING!!! Check to make sure all power sources are disconnected before starting any troubleshooting. Safety gloves and glasses should be worn when working on the unit. Serious injury or death may occur if safety precautions are not followed. RH-W Series Light Issue (All not 1.
PART LIST / REPLACEMENT PART LIST / REPLACEMENT Description Description Duct cover bracket Transformer Duct cover Capacitor Hood bracket Transition collar Hood body assembly Squirrel cage motor Aluminum filter x 2 (30‖ model only) LED lights Aluminum filter x 3 (36‖ model only) Control switch...
For a period of one (1) year from the date of purchase, if the product is determined to be defective, Windster will attempt to repair the product, at its option, at no charge. After the warranty period, customer must pay for all labor charges. During the "labor"...