Graco PrecisionSwirl 243402 Instructions-Parts List Manual page 16

Orbital dispenser
Hide thumbs Also See for PrecisionSwirl 243402:
Table of Contents

Advertisement

Service
16. To reconnect power to the orbital dispenser, per-
form steps a and b as follows:
a. Reconnect the motor control cable to the control
assembly.
b. At the control assembly, move the MAIN power
switch to the ON position.
17. Turn on the material supply to the orbital dispenser.
18. Verify that the orbital dispenser operates correctly.
The new orbiter coupler bearing may require a
short break-in period before startup. Run the swirl
applicator for 15 minutes at 6600 rpm (no dispens-
ing required). This will ensure the orbiter reaches
normal operation status sooner.
19. Return the orbital dispenser to normal operating
condition.
16
Bellows Seal Replacement
1. Clean excess material from the bellows seal (140)
and nozzle guard (80).
2. Remove the nozzle guard (80).
3. Remove the nozzle (15).
4. Lift the bellows seal (140) and pull it over the
threads on the fluid tube (13).
5. Inspect the surface of the tube bearing. If there are
any signs of material contamination, replace the
tube bearing and increase the frequency of the seal
replacement.
309403R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents