Coupler Assembly Replacement

There are three ball bearing assemblies in the Preci-
sionSwirl orbital dispenser - two in the motor and one in
the motor coupling for tube support.
Only the orbiter coupling and its bearing may be
removed and replaced. If the motor bearings need to be
replaced, the entire motor requires replacement. The
tube support coupler (24) should not be removed unless
a new replacement coupler assembly is available.
Replace the complete coupler assembly, do not attempt
to replace the bearing only.
The repair technician must use the proper tools to
avoid damaging the bearings. Tools are provided in
bearing repair tool kit 241569.
Coupler Assembly Removal
Before removing the coupler assembly (24), you
must remove the bearing from the coupler.
1. Place motor assembly onto the coupling support
tool. Refer to F
. 2.
IG
2. Use the push rod tool to press the bearing out of the
coupler. The push rod tool is the 4-in. piece of bar
stock included in Kit 241569. Discard the bearing.
Do not use the coupler removal tool to remove the
bearing.
Push rod tool
Tube support
bearing
F
. 2: Coupler Assembly Removal
IG
309403R
3. Use the gear puller and coupler removal tool
F
IG
Motor
assembly
Orbiter coupler
assembly
Coupling
support tool
TI10658_1
included in Kit 241569 to separate the coupler from
the motor shaft. Discard the coupler. Refer to F
Align pin in the coupler removal tool with slots in
coupler.
Orbiter
coupler
removal tool
. 3: Remove Orbiter Coupler
Service
. 3.
IG
TI10658b
13