Brinkmann Cutter pumps of the series SPC820 Contents 9 Trouble shooter’s guide ........7 Indication to the manual ........2 Description of product ........2-3 10 Spare part ............8-9 Safety instructions ..........4 11 Repair ............... 9 Transport and storage ........4 12 Disposal ............
Page 3
/ spec. Type weight 1 l/min H mm h mm SPC820 / 230 3.3 / 3.8 / 330 / 460 1) Dimensions in accordance with page 5 The motor is surface-cooled and compliant with DIN IEC 34 and EN 60034 (protection degree IP 55).
• Guards for moving parts (e.g. coupling) must not 3 Safety instructions be removed from the machine while in opera- When operating the pump, the safety instructions contained in this manual, the relevant national tion. accident prevention regulations and any other •...
Electric wiring 5 Installation and Connection Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. All service work must be carried out by qualified Pumps must be mounted securely. Piping, tank and service personnel.
6 Start up / Shut down Start up ATTENTION Switch off at the mains. The pump may only be operated if installed to a After connection the electrical wires, close the terminal suitable tank! box. Briefly start the motor (max. 30 sec.) and check Unwanted objects, such as broken tools or the rotation according to the arrow on the top of the indexing plates which still lie under the pump...
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series SPC820 Item Description Stator with terminal board Motor flange End shield Terminal box Fan cover Ball bearing DIN 628 10 Ball bearing DIN 625 11 Gasket...
(inside) and the motor shaft (3). They must not be lubricated or oiled. 1. Pumptype e.g. SPC820 / 330 – Set the pump down on the end of the shaft. 2. Pump No. – Position the shaft clamp (1) (use a new shaft e.g.
Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Cutter Pumps Type SPC820 The named product described above complies with the following statutory requirements of United Kingdom: UK SI 2008 No.
Page 11
Produktbezeichnung / Product name / Désignation du produit / Designación del producto Cutterpumpen / Cutter Pumps / Pompes Broyeuses / Bombas Trituradoras Typ / Type / Tipo SPC820 Das bezeichnete Produkt stimmt mit den folgenden Richtlinien des Rates zur Angleichung der Rechtsvorschriften der EG-Mitgliedsstaaten überein: The named product conforms to the following Council Directives on approximation of laws of the EEC Member States: Le produit sus-mentionné...