Dormakaba ED100 Owner's Manual

Dormakaba ED100 Owner's Manual

Automatic swing door operators
Hide thumbs Also See for ED100:

Advertisement

ED100/ED250
Automatic swing door operators
Owner's Manual
DL4614-030 – 02-2018
| EN |

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ED100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba ED100

  • Page 1 ED100/ED250 Automatic swing door operators Owner's Manual DL4614-030 – 02-2018 | EN |...
  • Page 2: Table Of Contents

    ED100/ED250 Owner's Manual Table of Contents Table of contents Table of contents General information To our customers What you should know Distributor information Knowing act Program switch panel AAADM Safety information labels Safety label, automatic swinging doors Safety label, low energy swinging doors...
  • Page 3: General Information

    ED100 header for low energy power operated The purpose of this manual is to familiarize you with pedestrian doors. your ED100 or ED250 automatic swing door system. • ED100 header full power, for power operated It is essential that you "know your system" and that you pedestrian doors.
  • Page 4: What You Should Know

    3.3 Program switch panel 3.1.1 dormakaba USA, Inc. distributor information. 3.3.1 Program switch door control modes. Be sure that the dormakaba USA, Inc. distributor has 1. Auto, door opens when actuated by: provided the following information for each door •...
  • Page 5: Aaadm Safety Information Labels

    These minimum safety checks, by an ED100 configured for full energy or an ED250 Owner’s Manual, should be in addition to those in the made each day and after any operator.
  • Page 6: Daily Safety Check Procedure

    ED100/ED250 Owner's Manual Chapter 5 5 Daily safety check procedure 5.1 Power operated swing doors Fig. 5.1.1 One way traffic, overhead mounted presence sensor NOTICE One way traffic Clear door opening All figures and diagrams are for purposes of...
  • Page 7 ED100/ED250 Owner's Manual Chapter 5 5.1.3 Floor mat activation and safety, one way traffic Fig. 5.1.3 Floor mat activation, single door 1. Step on the opening "activating" mat, door should: Door opening • Open smoothly. • Stop at fully open without impact.
  • Page 8: Low Energy Power Operated Swing Doors

    These daily safety checks are also listed in Chapter 4, hardware should be in good condition. Safety Information labels, low energy swinging doors. 5. Have door inspected by a dormakaba USA Inc. AAADM certified technician at least annually. 1. Activate the door by a knowing act (Para.3.3).
  • Page 9: General Safety Related Items

    ED100/ED250 Owner's Manual Chapter 6 6 General safety related items 6.1 Power operated swing doors Fig. 6.1.1 Guide rails, jamb and floor mounted Width of door 6.1.1 Review safety related items and perform checks minimum periodically as noted. TIPS AND RECOMMENDATIONS 30”...
  • Page 10: Low Energy Power Operated Swing Doors

    4. Door safety signage a safe manner. • Refer to Chapter 7 for door safety signage Call your local dormakaba USA, Inc. distributor requirements. Chapter 4 documents safety for repair. information (daily safety check) and annual compliance inspection labels requirements.
  • Page 11: Ed100/Ed250 Door Signage

    ED100/ED250 Owner's Manual Chapter 7 7 ED100/ED250 door signage 7.1 Full energy operators 7.2 Low energy operator, ED100 7.1.1 Overview 7.2.1 Overview Signage and warnings are specified in ANSI /BHMA Signage and warnings are specified in ANSI /BHMA A156.10, American National Standard for power A156.19, American National Standard for power assist...
  • Page 12: Door Signage, Full Energy Single Swing Door

    ED100/ED250 Owner's Manual Chapter 7 7.3 Door signage, full energy single swing door Fig. 7.3.1 Full energy decals, one way traffic Fig. 7.3.2 Full energy decals, two way traffic Approach Non-approach DD0739-020 7.4 Door signage, low energy single swing door Fig.
  • Page 13: Door Signage, Full Energy Double Swing Doors

    ED100/ED250 Owner's Manual Chapter 7 7.5 Door signage, full energy double swing doors Fig. 7.5.1 One way traffic, approach side Fig. 7.5.2 One way traffic, non-approach side DD0739-020 DD0739-020 50” ± 12” 50” ± 12” Fig. 7.5.3 Two way traffic, approach side Fig.
  • Page 14 ED100/ED250 Owner's Manual Chapter 7 Fig. 7.5.7 One way traffic, approach side Fig. 7.5.8 One way traffic, non-approach side DD0739-020 DD0739-020 50” ± 12” 50” ± 12” Fig. 7.5.9 Double egress, RH, one way traffic Fig. 7.5.10 Double egress, RH, one way traffic...
  • Page 15: Door Signage, Low Energy Double Swing Doors

    ED100/ED250 Owner's Manual Chapter 7 7.6 Door signage, low energy double swing doors Fig. 7.6.1 Knowing act, non-hinge side Fig. 7.6.2 Knowing act, hinge side 50” ± 12” 50” ± 12” Fig. 7.6.3 Push/pull, push to operate Fig. 7.6.4 Push/pull, pull to operate 50”...
  • Page 16: Ed100/Ed250 Header Cleaning

    8 ED100/ED250 header cleaning 8.1 ED100/ED250 environment and cleaning 8.1.1 ED100/ED250 environmental requirements. Table 8.3.1 Operator environmental requirements ED100/ED250 header assembly is designed to operate Ambient temperature 5 to 122 °F on an interior building surface under the specifications shown in Table 8.3.1.
  • Page 17 ED100/ED250 Owner's Manual Blank page This page left intentionally blank. ED100/ED250 DL4614-030 02-2018...
  • Page 18 USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 T: 717-336-3881 www.dormakaba.com F: 717-336-2106...

This manual is also suitable for:

Ed250

Table of Contents