Dormakaba ED50 Owner's Manual

Dormakaba ED50 Owner's Manual

Swing door operators
Hide thumbs Also See for ED50:

Advertisement

Quick Links

ED50/ED100/ED250
Swing Door Operators
Narrow Header
Owner's Manual
DL4616-007 – 09-2021
| EN |

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ED50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba ED50

  • Page 1 ED50/ED100/ED250 Swing Door Operators Narrow Header Owner's Manual DL4616-007 – 09-2021 | EN |...
  • Page 2: Table Of Contents

    ED50/ED100/ED250 Owner's Manual Table of Contents Narrow header Table of contents Table of contents General information To our customers What you should know Distributor information ED50 low energy operator ED100/ED250 operator power configuration Low energy power operated swinging doors ANSI/BHMA A156.19...
  • Page 3: General Information

    Chapter 1 Narrow header 1 General information 1.1 Owner's Manual Fig.1.1 ED50/ED100/ED250 narrow header This Owner's manual applies to ED50/ED100/ED250 dormakaba swing door operators packaged in a surface applied narrow header. 1.2 ED50/ED100/ED250 narrow header installation. NOTICE Fig.1.2 ED100/ED250 operator Interior building surface installation.
  • Page 4: To Our Customers

    Narrow header 2 To our customers 2.1 Service availability. We are pleased that a dormakaba ED50/ED100/ED250 narrow header swing door system has been selected for dormakaba USA, Inc. has a nationwide network of this installation. dormakaba designed, tested and built authorized distributors for sales, installation and service the system to provide many years of service.
  • Page 5: What You Should Know

    3.1 Distributor information 3.2 ED50 low energy operator 3.1.1 dormakaba USA, Inc. distributor information. ED50 operator is available only as a low energy operator Be sure that the dormakaba USA, Inc. distributor has (Para. 3.4). provided the following information for each door 3.3 ED100/ED250 operator power...
  • Page 6: Mode Switch And Exit Only Switch Panel

    ED50/ED100/ED250 Owner's Manual Chapter 3 Narrow header Mode switch and Exit Only switch panel Fig. 3.6.1 Mode switch panel Fig. 3.6.7 Optional key switch panels Mode switch panel Mode switch, three position Exit Only switch, two position RJ45 Comm port for service 3.6.1 Mode switch...
  • Page 7: Aaadm Safety Information Labels

    The appropriate and the hardware should by an ED50 operator or an ED100/ED250 operator be in good condition. signage should be present. configured for low energy. 7. Have door inspected by an 6.
  • Page 8: Daily Safety Check Procedure

    ED50/ED100/ED250 Owner's Manual Chapter 5 Narrow header 5 Daily safety check procedure 5.1 Power operated swing doors Fig. 5.1.1 One way traffic, overhead mounted presence sensor (ANSI/BHMA A156.10) One way traffic Clear door NOTICE opening All figures and diagrams are for purposes of...
  • Page 9: Low Energy Power Operated Swing Doors (Ansi/Bhma A156.19)

    These daily safety checks are also listed in Chapter 4, 5. Have door inspected by a dormakaba USA Inc. Safety Information labels, low energy swinging doors. AAADM certified technician at least annually.
  • Page 10: General Safety Related Items

    • There should be no looseness in the door pivots or in a safe manner. connections between door and operator. Call your local dormakaba USA, Inc. distributor 7. Breakout stop for repair. • Center pivoted in swinging doors may be supplied...
  • Page 11: Low Energy Power Operated Swing Doors (Ansi/Bhma A156.19)

    3. Door closing force a safe manner. • Force to prevent the door from closing should not Call your local dormakaba USA, Inc. distributor exceed 15 pounds measured with a force gauge. for repair. 4. Door safety signage •...
  • Page 12: Ed50/Ed100/Ed250 Door Signage

    "ACTIVATE SWITCH TO OPERATE" on side of door having knowing act switch or other knowing act device. ED50 operator and ED100/ED250 operator configured for low energy 7.2.1 Overview Fig. 7.2.1 AUTOMATIC CAUTION DOOR decal Signage and warnings are specified in ANSI /BHMA A156.19, American National Standard for...
  • Page 13: Door Signage, Full Energy Single Swing Doors

    ED50/ED100/ED250 Owner's Manual Chapter 7 Narrow header 7.3 Door signage, full energy single swing doors Fig. 7.3.1 One decal, one way traffic Fig. 7.3.2 One decal, two way traffic Approach Non-approach Non-swing side Swing side DO NOT AUTOMATIC CAUTION...
  • Page 14: Door Signage, Full Energy Double Swing Doors

    ED50/ED100/ED250 Owner's Manual Chapter 7 Narrow header 7.5 Door signage, full energy double swing doors Fig. 7.5.1 One way traffic, approach side Fig. 7.5.2 One way traffic, non-approach side DO NOT DO NOT ENTER ENTER dormakaba dormakaba AUTOMATIC AUTOMATIC...
  • Page 15 ED50/ED100/ED250 Owner's Manual Chapter 7 Narrow header Fig. 7.5.7 Double egress, RH, one way traffic, interior Fig. 7.5.8 Double egress, RH, one way traffic, exterior Swing side Approach side Swing side Approach side DO NOT DO NOT ENTER ENTER...
  • Page 16: Door Signage, Low Energy Double Swing Doors

    ED50/ED100/ED250 Owner's Manual Chapter 7 Narrow header 7.6 Door signage, low energy double swing doors Fig. 7.6.1 Knowing act, SA header side Fig. 7.6.2 Knowing act, hinge side AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC CAUTION CAUTION CAUTION CAUTION DOOR DOOR DOOR...
  • Page 17: Ed50/Ed100/Ed250Maintenance

    Off, internal 24 Vdc power is Off. WARNING If there are any problems, discontinue door operation immediately and secure the door in Red LED a safe manner. Yellow LED Call your local dormakaba USA Inc. distributor Green LED for repair. ED50/ED100/ED250 DL4616-007 09-2021...
  • Page 18 USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 T: 717-336-3881 F: 717-336-2106 www.dormakaba.us...

This manual is also suitable for:

Ed100Ed250

Table of Contents