Fill Pump - Graco SaniSpray HP 65 Operation - Repair - Parts

Portable hopper sprayer
Hide thumbs Also See for SaniSpray HP 65:
Table of Contents

Advertisement

6.
Turn ON/OFF Switch to ON position.
7.
Rotate Pressure Control Knob clockwise
until the pump turns on.
8.
When sprayer starts pumping, water and
air bubbles will be purged from system.
Allow fluid to flow out of Drain Tube and
into waste bucket until Hopper is nearly
empty.
9.
Turn ON/OFF Switch to OFF position.
3A7653D

Fill Pump

Refer to disinfectant label for manufacturer's
directions on proper use. If dilution is
required, properly dilute disinfectant prior to
use.
1.
Add properly prepared disinfectant to the
Hopper.
2.
Turn ON/OFF Switch to ON position.
3.
Wait to see disinfectant coming out of the
Drain Tube.
4.
Turn ON/OFF Switch to OFF position.
NOTE: Pump may prime faster if the
ON/OFF Switch is momentarily turned
off so the pump can slow and stop.
Turn ON/OFF Switch on and off several
times if necessary.
Start Up