Start Up
6.
Turn ON/OFF Switch to ON position.
7.
Rotate Pressure Control Knob clockwise
until the pump turns on.
8.
When sprayer starts pumping, water and
air bubbles will be purged from system.
Allow fluid to flow out of Drain Tube and
into waste bucket until Hopper is nearly
empty.
9.
Turn ON/OFF Switch to OFF position.

Fill Pump

1.
Add disinfectant to the Hopper.
2.
Turn ON/OFF Switch to ON position.
3.
Wait to see disinfectant coming out of the
Drain Tube.
4.
Turn ON/OFF Switch to OFF position.
NOTE: Pump may prime faster if the
ON/OFF Switch is momentarily turned
off so the pump can slow and stop.
Turn ON/OFF Switch on and off several
times if necessary.
14
Fill Spray Gun and Airless
Hose
1.
Hold Spray Gun against waste bucket.
Point Spray Gun into waste bucket.
a.
Disengage Trigger Lock.
b.
Pull and hold Spray Gun trigger.
c.
Turn Prime/Spray Valve up to
SPRAY position.
d.
Turn ON/OFF Switch to ON posi-
tion.
2.
Trigger Spray Gun into waste bucket
until only disinfectant comes out.
3.
Release trigger. Engage Trigger Lock.
High-pressure spray is able to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.
4.
Inspect Airless Hose connections for
leaks. If leaks occur, perform Pressure
Relief Procedure, page 11, then tighten
all fittings and repeat Start Up. If there
are no leaks, continue with the next step.