9.
Increase pressure 1/2 turn to start
motor. Allow paint or other material to
circulate through sprayer until material
flows out of the drain tube.
10. When sprayer starts pumping, flush fluid
and air bubbles will be purged from
system. Allow fluid to flow out of drain
tube into waste pail for 30 to 60
seconds.
11. Turn ON/OFF switch to OFF position.
Power button is NOT illuminated when
OFF.
High-pressure spray is able to inject
toxins into the body and cause serious
bodily injury. Do not stop leaks with hand
or rag.
12. Inspect for leaks. If leaks occur, perform
Pressure Relief Procedure, page 10,
then tighten all fittings. If there are no
leaks, continue with the next step.
3A9031D

Fill Pump

1.
Move siphon tube to paint pail and
submerge siphon tube in paint.
2.
Turn ON/OFF switch to ON position.
Power button is illuminated when ON.
3.
Wait to see paint coming out of the drain
tube.
4.
Turn ON/OFF switch to OFF position.
Power button is NOT illuminated when
OFF.
NOTE: Some fluids may prime faster if the
ON/OFF switch is momentarily turned off so
the pump can slow and stop. Turn ON/OFF
switch on and off several times if necessary.