Circulating Pump - DeDietrich ALEZIO S V200 User Manual

Reversible air/water split inverter heat pump
Hide thumbs Also See for ALEZIO S V200:
Table of Contents

Advertisement

Product name
T
= +2 °C
j
T
= +7 °C
j
T
= +12 °C
j
T
= bivalent temperature
j
T
= operation limit temperature
j
Operation limit temperature for air-to-water
heat pumps
Heating water operating limit temperature
Electrical power consumption
Off mode
Thermostat-off mode
Stand-by
Crankcase heater mode
Supplementary heater
Rated heat output
Type of energy input
Other specifications
Capacity control
Sound power level, indoors - outdoors
Annual energy consumption under average
conditions
Annual energy consumption under colder con­
ditions
Annual energy consumption under warmer
conditions
Rated air flow rate, outdoors for air-to-water
heat pumps
Declared load profile
Daily electricity consumption
Annual electricity consumption
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
(1) The rated heat output
Psup is equal to the supplementary capacity for heating sup(Tj) .
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
(2) If
7748661 - v03 - 08062020
Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary heater
AWHP 11 MR-2
AWHP 11 TR-2
(cycle L)
COPd
-
3.17
COPd
-
4.54
COPd
-
6.19
COPd
-
1.20
COPd
-
1.20
TOL
°C
-10
WTOL
°C
60
P
kW
0.009
OFF
P
kW
0.023
TO
P
kW
0.021
SB
P
kW
0.055
CK
Psup
kW
0.0
Electricity
Variable
L
dB
48–69
WA
Q
kWh
3999
HE
Q
kWh
3804
HE
Q
kWh
2580
HE
6000
3
m
/h
L
Q
kWh
4.285
elec
AEC
kWh
899
ƞ
%
114.00
wh
Q
kWh
0.000
fuel
AFC
GJ
0
See
The back cover for contact details.
3.2.5

Circulating pump

Important
The benchmark for the most efficient circulating pumps is EEI ≤
0.20.
The circulating pump in the indoor unit is a variable speed pump. It adapts
its speed to the distribution network.
3 Technical specifications
AWHP 16 MR-2
AWHP 16 TR-2
(cycle L)
3.02
4.34
5.75
1.35
1.35
-10
60
0.009
0.035
0.021
0.055
0.0
Electricity
Variable
48 – 70
5861
5684
4120
6000
L
4.285
899
114.00
0.000
0
MIV-S V200