Diagram - Liquid System; Control Unit; Evc Control Unit - Hardi RANGER PRO Instruction Book

Table of Contents

Advertisement

3 - Description

Diagram - Liquid system

1. Suction filter (optional)
2. Suction manifold
3. Pump
4. Pressure manifold
5. Agitation
6. Safety valve
7. HARDI-MATIC
8. Cyclone filter (optional)
9. Off/On/Purge valve

Control unit

The system is based on EVC - Electrical Valve Control. The on/off is linked to the section valves, which is resulting in a very
quick response to on/off. The operating unit is constructed of modules and is electrically controlled via a remote control
box.
The built-in HARDI-MATIC ensures a constant volume per hectare of the liquid (l/ha) at varying forward speed within the
same gear when the number of P.T.O. revolutions are between 300-600 r.p.m. (pump 540 r.p.m) or 650-1100 r.p.m. (pump
1000 r.p.m.).

EVC control unit

EVC - Electrical Valve Control. The ON/OFF is linked to the section valves, which results in a very quick response to
ON/OFF. The operating unit is constructed of modules and is electrically controlled via a remote control box. The unit is fit
with build-in HARDI MATIC.
3.6
10. Check valves
11. Boom section valves
12. Boom
13. Rinse tank (optional)
14. Quick fill (optional)
15. HARDI FILLER (optional)
16. Tank rinse nozzle (optional)
17. Boom pressure gauge