Installer Setting - Thermistor - LG ABNQ18GM1T0 Installation Manual

Hide thumbs Also See for ABNQ18GM1T0:
Table of Contents

Advertisement

OPTIONAL OPERATION
30

Installer Setting - Thermistor

This is the function to select the temperature sensor to judge the room temperature.
<Thermistor Table>
Temperature sensor selection
01
Remote controller
02
Indoor unit
Cooling
03
2TH
Heating
* The function of 2TH has different operation characteristics according to the product.
Press and hold
1
than 3 seconds to enter the installer
settings mode.
- If pressing only once briefly, it will
enter the user settings mode.
Make sure to press and hold for more
than 3 seconds.
Move to the Selection of Indoor Temperature
2
Sensor (Thermistor) in the menu using
button and then, it displays as below.
Select the location of indoor temperature
3
sensor (Thermistor) using
Code value for
Room temperature
sensor (Thermistor)
Press
4
Press
5
If no button is selected for about
25 seconds after setup, it exits the setup
mode automatically.
If the
exit, the changes will not apply.
Operation in remote controller temperature sensor
Operation in indoor unit temperature sensor
Operation of higher temperature by comparing indoor unit's
and wired remote controller's temperature. (There are
products that operate at a lower temperature.)
Operation of lower temperature by comparing indoor unit's
and wired remote controller's temperature.
button for more
Set value
Set value for sensor location
01 : Remote control
02 : Indoor unit
03 : 2TH
button to save the setting.
button to exit.
button is not selected before you
Function
button.

Advertisement

Table of Contents
loading