Installer Setting - Thermistor - LG ABNW24GM1E4 Installation Manual

Table of Contents

Advertisement

INSTALLATION INSTRUCTION
24

Installer Setting - Thermistor

This function is to test the room temperature by selecting a temperature sensor.
• The function setting method is slightly different for various products. Please refer to the
corresponding product manual for details.
Settings - temperature
1
Pressing the
key and
simultaneously for more than 3 seconds can
enter the manual setting mode of the system.
- After entering the manual setting mode,
select the setting code of the temperature
sensor by pressing
* Code value of the temperature sensor: 04
2
Use the temperature adjustment key to set
code value of the temperature sensor up (
and down (
).
Press the
key to save the setting value.
3
4
Press the
key and
for more than 3 seconds in the setting state to
exit the manual setting mode.
- If there is no key input within 25 seconds, the
system will also exit the manual setting
mode.
key
key.
* Setting value
01: Wired controller
sense
02: Indoor unit sense
Code
03: Joint sense of the
value
wired controller and
Value
the indoor unit
key simultaneously
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Abnw30gm1e4Abnw36gm2e4

Table of Contents