Installer Setting - Ceiling Height Selection - LG ABNQ18GM1T0 Installation Manual

Hide thumbs Also See for ABNQ18GM1T0:
Table of Contents

Advertisement

Installer Setting - Ceiling Height Selection

This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product)
FAN
SPEED
TEMP
- As the ceiling height setting standard
can be different in accordance with the
products, refer to the product instruction
manual for its detail.
<Ceiling Height Selection Table>
Ceiling Height Level
01
Low
02
Standard
03
High
04
Very high
- Ceiling height setting is available only for some products.
- Ceiling height of 'Very high' function may not exist depending on the indoor unit.
- Refer to the product manual for more details.
1
2
OPER
MODE
3
4
Decrease the indoor airflow rate 1 step from standard level
Set the indoor airflow rate as standard level
Increase indoor airflow rate 1 step from standard level
Increase indoor airflow rate 2 steps from standard level
INSTALLATION INSTRUCTION
When pressing the
button simultaneously for more than 3
seconds, the system will be entered
into the installer setting mode.
- After entering into the installer setting
mode, select the ceiling height setting
code value by pressing the
* Ceiling height setting code value : 05
Select the desired setting value with the
temperature up(▲), down(▼) button.
Code value
Value
When pressing the
currently established ceiling height value
will be set up.
When pressing the
button simultaneously for more than 3
seconds after the setting has been completed,
the setting mode will be released.
- If there isn't any button input for more
than 25 seconds, the installer setting
mode will also be released.
Description
25
OPER
button and
MODE
button.
OPER
MODE
*Setting value
01: Low
02: Standard
03: High
04: Very high
button,
OPER
button and
MODE

Advertisement