Minebea Intec Puro EF-4PLLP-1500 Operating Instructions Manual

Minebea Intec Puro EF-4PLLP-1500 Operating Instructions Manual

Floor scale
Hide thumbs Also See for Puro EF-4PLLP-1500:

Advertisement

Quick Links

Operating Instructions
Floor scale Puro®
98628-000-67 Edition 1.0.0
03/05/2020
Checked on the basis of Puro® scale with software version 2.89
Minebea Intec Bovenden GmbH & Co. KG, Leinetal 2, 37120 Bovenden, Germany
Phone: +49.551.309.83.0 Fax: +49.551.309.83.190

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Puro EF-4PLLP-1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Minebea Intec Puro EF-4PLLP-1500

  • Page 1 Operating Instructions Floor scale Puro® 98628-000-67 Edition 1.0.0 03/05/2020 Checked on the basis of Puro® scale with software version 2.89 Minebea Intec Bovenden GmbH & Co. KG, Leinetal 2, 37120 Bovenden, Germany Phone: +49.551.309.83.0 Fax: +49.551.309.83.190...
  • Page 2 Any information in this document is subject to change without notice and does not represent a commitment on the part of Minebea Intec unless legally prescribed. This product should only be operated/installed by trained and qualified personnel. In correspondence concerning this product, the type, name, and release number/serial number as well as all license numbers relating to the product have to be cited.
  • Page 3: Table Of Contents

    Application Programs ...............................12 5.2.1 Weighing Mode ...............................12 5.2.2 Counting Mode............................... 14 5.2.3 Check Mode ..............................16 5.2.4 Totalizing and Statistics Mode........................24 Menu Settings............................ 29 Menu Mode................................29 Menu Navigation ..............................30 6.2.1 Menu Selection [APPLIC]..........................30 6.2.2 Menu Selection [METRO]..........................31 Minebea Intec EN-1...
  • Page 4 Cleaning instructions.............................48 9.2.2 Cleaning agents..............................48 Disposal .............................49 Troubleshooting ..........................50 11.1 Service Information..............................50 Technical data .............................51 12.1 Ambient Conditions ..............................51 12.2 Specifications ................................51 12.3 Accessories ................................52 12.4 Dimensions ................................53 Appendix ............................59 13.1 Printouts ..................................59 13.2 FCC Note ..................................60 EN-2 Minebea Intec...
  • Page 5: Introduction

    WARNING indicates that death or severe, irreversible injury may occur if appropriate safety measures are not observed. Take the corresponding safety precautions. CAUTION Warning of personal injury. CAUTION indicates that minor, reversible injury may occur if appropriate safety measures are not observed. Take the corresponding safety precautions. Minebea Intec EN-3...
  • Page 6 Warning of damage to property and/or the environment. NOTICE indicates that damage to property and/or the environment may occur if appropriate safety measures are not observed. Take the corresponding safety precautions. Note: User tips, useful information, and notes. EN-4 Minebea Intec...
  • Page 7: Safety Instructions

    If there are grounds for a complaint, this must be brought to the attention of the delivery company immediately. A Minebea Intec sales or service point must be informed. Visit our website http://www.puroscales.com or contact your dealer.
  • Page 8: Device Installation

    For maximum operating time, the battery should be charged at room temperature. During battery operation, the battery symbol indicates the battery charge level remaining. The indicator will automatically turn off when the batteries are empty. EN-6 Minebea Intec...
  • Page 9: Connections

    A printer can be connected to the printer port on the side of the indicator. Mounting bracket Align the mounting bracket over the threaded holes in the side of the indicator and install the knobs. Adjust the indicator to the desired angle and tighten the knobs. Minebea Intec EN-7...
  • Page 10: Device Description

    4.1.1.2 Display elements LCD Display 10 11 Item Description Item Description Busy Low Average Piece Weight Plus symbol Low Sample Weight Minus symbol Data transfer Zero-setting Weight unit Counting Battery charge Weighing Warning symbol Checkweighing Printer Icon EN-8 Minebea Intec...
  • Page 11 Triggers a func- Sends the current second scale (when the weight or tion. value to the selected scale is off). display the COM ports if AUTO- Set zero (when accumulated PRINT is set to off. scale is on). information. Minebea Intec EN-9...
  • Page 12 Aborts the cali- items. play and advances to bration in pro- Decrement the the next available gress. digit. setting. Advances to Advances to the next the previous menu or item. digit in input Increment the digit. process. EN-10 Minebea Intec...
  • Page 13: Operation

    The application names are displayed every 2 seconds until the button is Mode released. If the button is released, the displayed application is selected and starts. Mode Possible applications are: [WEIGHT] normal weighing mode [COUNT] count mode Minebea Intec EN-11...
  • Page 14: Application Programs

    To select the weighing mode, press and hold the button until [WEIGHT] is Mode displayed with application icon appear at bottom of the screen. Release the button. The application is activated. [0.000] is displayed. 2. Place container on the scale (in this example, 0.598 kg). EN-12 Minebea Intec...
  • Page 15 Unit displayed, when these units are activated in menu before. [kg / g / lb /oz / lb:oz]. Release the button to select. Possible units are: gram kilogram [kg] pound [lb] ounce [oz] pound-ounces [lb:oz] Minebea Intec EN-13...
  • Page 16: Counting Mode

    7. Press the (Yes) button to confirm reference sample quantity. 8. If the pan is empty, then [PUT.PW] (put reference) is shown on the display. Put the desired reference quantity on the pan and go on at step 7. EN-14 Minebea Intec...
  • Page 17 10. Counting is initialized. On the display, the actual number of pieces is shown: [20 pcs]for example. 11. Replace the reference sample with the test sample. The display shows the quantity of the sample count. 12. Press the button briefly. Mode Minebea Intec EN-15...
  • Page 18: Check Mode

    The different check modes must be activated prior via menu (see Chapter 6.2.1). 5.2.3.1 Check Weighing Mode Compare the weight of items to a targeted weight range. Example: The required target weighing range is between 1 kg (low limit) to 1.1 kg (high limit) EN-16 Minebea Intec...
  • Page 19 5. Press the (No) button to edit the value. Unit The first digit is blinking [_00.000]. 6. Press the (Yes) button to accept and highlight the next digit (or press the Menu (exit) button to go back one digit). Minebea Intec EN-17...
  • Page 20 The Display will show the high limit value with all digit blinking [001.100] (in this example, 1.100 kg). 11. Press the (Yes) button to accept high limit value. In case the check limit values are wrongly set, [LIM.ERR] (limit error) will be displayed briefly followed by [CLR.LIM] (clear limit). EN-18 Minebea Intec...
  • Page 21 1,100 kg), press the button briefly at anytime during Mode check weighing process. The scale displays the low limit value with yellow LED light briefly and the high limit value with red LED light briefly. Minebea Intec EN-19...
  • Page 22 (No) button (increment) to toggle the choices [10, 20, 50, 100, Unit 200]. 5. Press the (Yes) button to confirm reference sample quantity. If the pan is empty [PUT.PW] (put piece weight) is shown on the display. EN-20 Minebea Intec...
  • Page 23 (Yes) button to set the low limit. The Display will show stored low limit with all digit blinking [000000] (in this example, 0 pcs). 10. Press the (No) button to edit the value. Unit The first digit is blinking [ _00000]. Minebea Intec EN-21...
  • Page 24 The Display will show the high limit value with all digit flashing [00510.0] (in this example, 510 pcs). 18. Press the (Yes) button to accept high limit value. The scale is ready for check counting application with new checklimit. Go on step EN-22 Minebea Intec...
  • Page 25 21. Place container on the scale (in this example, 109 pcs). Taring the container on scale. 22. Press the button with [NET] appear beside the weight value. 23. Place sample in the container. Minebea Intec EN-23...
  • Page 26: Totalizing And Statistics Mode

    Totalization manual is set to ON by default. 5.2.4.1 Procedure on Setting up the Totalization Application To enter into menu mode, press and hold the button until [M.E.N.U] is Menu displayed. Release the button. The 1 menu item [APPLIC] shown on display. EN-24 Minebea Intec...
  • Page 27 Menu 5.2.4.2 (Totalization) Displayed Values The Totalization Mode is active when icon is displayed. Put the first item on the scale. 2. Press the button to add the weight to accumulation data (under manual mode). Menu Minebea Intec EN-25...
  • Page 28 4. Put another sample on scale and follow same operation (Automatic or Manual mode). icon will keep flashing until the weight is removed. 5.2.4.3 Viewing and Clearing Statistical Data The pan must be empty to view the stored statistics. Empty the weighing pan. EN-26 Minebea Intec...
  • Page 29 Totalized value (TOTAL = 5.225 kg) Minimum value (Min = 0.470 kg): Maximum value (Max = 1.485 kg) To clear the totalizing memory: 3. Press and hold the button while the pan is unloaded and the totalizing data is displayed. Minebea Intec EN-27...
  • Page 30 Gross loads and net loads cannot be added to the same total. If the first load is a gross weight, following loads must also be gross weights. If the first load is a net weight, following loads must also be net weights. EN-28 Minebea Intec...
  • Page 31: Menu Settings

    When viewing the setting (in this example [METRO] - [STAB.RA] value 0.5d). 4. When viewing the setting (in this example [METRO] - [STAB.RA] value 0.5d), press (Yes) button to Accept setting or the (No) button to change setting. The Unit current selection is signed by [⃘]. Minebea Intec EN-29...
  • Page 32: Menu Navigation

    Only activated units will be accessible with the (Mode) Button. Mode Default settings are identified by an "*" APPLIC — WEIGH Weighing mode — OFF disabled — ON enabled* — COUNT Count mode — OFF disabled — ON enabled* — CHECK Check mode EN-30 Minebea Intec...
  • Page 33: Menu Selection [Metro]

    Menu Selection [UNIT] Enter this menu to customize weighing unit to be used. Only activated units will be accessible with the (Unit) Button. Unit Default settings are identified by an "*" UNIT — kg Kilogram — OFF disabled Minebea Intec EN-31...
  • Page 34: Menu Selection [Op.func]

    Backlight off after 3 minutes of no activity — 5 SEC Backlight off after 5 minutes of no activity* — 8 SEC Backlight off after 8 minutes of no activity — D.LIGHT Display Backlight — OFF disabled — ON enabled EN-32 Minebea Intec...
  • Page 35: Menu Selection [Print]

    — HEADER Header info — OFF disabled* — ON enabled — FOOTER Footer info — OFF disabled* — ON enabled — MODE Mode info — OFF disabled* — ON enabled — INFO Reference info (CkWt, CkCount, Count) Minebea Intec EN-33...
  • Page 36: Menu Selection [Prn.com]

    — END Leave menu level 6.2.7 Menu Selection [PC.OUT] Enter this menu to define PC Output parameters. Default settings are identified by an "*" PC.OUT — MODE PC Output Mode — OFF disabled* — MAN.OUT Manual output EN-34 Minebea Intec...
  • Page 37: Menu Selection [Pc.com]

    — RESET Factory setting — NO not restored* — YES enabled — END Leave menu level 6.2.9 Menu Selection [CAL.ADJ] Enter this menu to perform calibration and adjustment of your scale (see chapter 7). CAL.ADJ — CAL Minebea Intec EN-35...
  • Page 38: Menu Selection [Info]

    — OFF Unlock* — ON Locked — S.CAL.AD Calibration / Adjustment Menu — OFF Unlock* — ON Locked — RESET Restore factory setting of current menu — OFF Unlock* — ON Locked — END Leave menu level EN-36 Minebea Intec...
  • Page 39: Calibration And Adjustment

    Unit Mode menu item. 3. Change menu item until [CAL.ADJ] is displayed. 4. Press (Yes) button to enter into sub-menu item. Sub-menu item [CAL] (Calibration) is displayed. Minebea Intec EN-37...
  • Page 40 8. For changing the calibration weight value, press the (No) button to edit the Unit value. The first digit is blinking [_015.000 kg]. 9. Press (Yes) button to accept and highlight the next digit. The 2nd digit is blinking [0_15.000 kg]. EN-38 Minebea Intec...
  • Page 41: Lin] Linearity Calibration Procedure

    [--C--] will be displayed while calibration weight is stored. In case of any mistake during the calibration process [CALE] (Calibration Error) is displayed. 14. Remove the weight after finish. The scale is ready for weighing. [LIN] Linearity Calibration Procedure Enter into Menu Mode: Minebea Intec EN-39...
  • Page 42 5. Change menu item until [LIN] shows on display. 6. Press (Yes) button to start zero point calibration. [0 kg] shows on display. [0] is blinking. 7. Empty the weighing pan. 8. Press the (Yes) button to confirm. EN-40 Minebea Intec...
  • Page 43 [00150.0] (in this example, 150 kg). 11. Put 2 linearization weight on the pan. 12. Press (Yes) button to start linearity adjustment at 100% of scale capacity. [--C--] is displayed while reading is stored. Minebea Intec EN-41...
  • Page 44: Geo] Geographical Factor Adjustment Procedure

    (Settings from 0 … 31 are available). Refer to table to determine the GEO factor that corresponds to your location. Enter into Menu Mode: Press and hold until [M.E.N.U] displayed. Menu Release the button. The 1 menu item [APPLIC] shown on display. EN-42 Minebea Intec...
  • Page 45 (Yes) button to return to sub-menu selections. 11. Press (No) button to return to the first item in the current menu. Unit 12. Press the button to exit the setup menu and return to the weighing mode. Menu Minebea Intec EN-43...
  • Page 46: Geo Code Table

    22°22' 23°54' 23°54' 25°21' 25°21' 26°45' 26°45' 28°06' 28°06' 29°25' 29°25' 30°41' 30°41' 31°56' 31°56' 33°09' 33°09' 34°21' 34°21' 35°31' 35°31' 36°41' 36°41' 37°50' 37°50' 38°58' 38°58' 40°05' 40°05' 41°12' 41°12' 42°19' 42°19' 43°26' 43°26' 44°32' 44°32' 45°38' EN-44 Minebea Intec...
  • Page 47 54°41' 54°41' 55°52' 55°52' 57°04' 57°04' 58°17' 58°17' 59°32' 58°17' 59°32' 60°49' 62°90' 62°90' 63°30' 63°30' 64°55' 64°55' 66°24' 66°24' 67°57' 67°57' 69°35' 69°35' 71°21' 71°21' 73°16' 73°16' 75°24' 75°24' 77°55' 77°55' 80°56' 80°56' 85°45' 85°45' 90°00' Minebea Intec EN-45...
  • Page 48: Sbi Interface

    There are some special response commands. These commands are used as standard responses. For example, error or confirmation. Special Response Commands always have the same size of 5 Bytes! The Scale confirmed the command execution without any errors. EN-46 Minebea Intec...
  • Page 49 8 SBI Interface Floor scale Puro® ERROR The Scale has reported an Error during command execution. LOCKED The command can not be executed because the parameter is currently locked. Minebea Intec EN-47...
  • Page 50: Maintenance/Repairs/Cleaning

    Suitable cleaning agents for the painted version: standard soft brooms and hand brushes, compressed air, damp cloths, detergents, all-purpose cleaners for adhering dirt. Cleaning agents suitable for the stainless steel version: Chlorine cleaner with max. 6 % chlorine content All‑purpose cleaner Industrial cleaners EN-48 Minebea Intec...
  • Page 51: Disposal

    Before disposing of or scrapping the product, any batteries should be removed and taken to a suitable collection point. Please see our T&Cs for further information. We reserve the right not to accept products that are contaminated with hazardous substances (ABC contamination) for repair. Minebea Intec EN-49...
  • Page 52: Troubleshooting

    Floor scale Puro® 11 Troubleshooting 11 Troubleshooting 11.1 Service Information If the troubleshooting chapter does not resolve or describe your problem, contact your authorized service agent. Please visit our website http://www.puroscales.com to locate the office nearest you. EN-50 Minebea Intec...
  • Page 53: Technical Data

    Off, 0.5, 1 or 3 divisions Power 100-240 V ~ 50/60 Hz AC adapter or internal rechargeable lithium battery Battery operation Up to 200 hours operation time (with standard battery) between recharges with 12 hour recharge time Calibration External, with calibration weights Minebea Intec EN-51...
  • Page 54: Accessories

    1,580 x 1,580 x 255 Shipping weight (kg) 12.3 Accessories Option Order-No. Lithium battery pack: Battery pack small compact scales 4 cells standard capacity YP-BPS4S Battery pack large compact scales 6 cells standard capacity YP-BPL6S Data printer: Brightek WHT2BR10 YP-DP1 EN-52 Minebea Intec...
  • Page 55: Dimensions

    12 Technical data Floor scale Puro® 12.4 Dimensions EF-4P Minebea Intec EN-53...
  • Page 56 Floor scale Puro® 12 Technical data all dimensions in mm / inch all dimensions in mm / inch all dimensions in mm / inch EN-54 Minebea Intec...
  • Page 57 12 Technical data Floor scale Puro® all dimensions in mm / inch Minebea Intec EN-55...
  • Page 58 Floor scale Puro® 12 Technical data EF-4PLLP-1500 all dimensions in mm EF-4PLLS-1500 all dimensions in mm EN-56 Minebea Intec...
  • Page 59 12 Technical data Floor scale Puro® EF-4PNNP-1500/3000 all dimensions in mm EF-4PNNS-1500/3000 all dimensions in mm Minebea Intec EN-57...
  • Page 60 Floor scale Puro® 12 Technical data EF-4PRRP-1500/3000 all dimensions in mm EF-4PRRS-1500/3000 all dimensions in mm EN-58 Minebea Intec...
  • Page 61: Appendix

    Accumulation line If Printx → Content → Total is All or Result MIN: 11.11 kg Accumulation line If Printx → Content → Total is All MAX: 14.85 kg Accumulation line If Printx → Content → Total is All Minebea Intec EN-59...
  • Page 62: Fcc Note

    Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. EN-60 Minebea Intec...
  • Page 63 Published by Minebea Intec Bovenden GmbH & Co. KG | Leinetal 2 | 37120 Bovenden, Germany Phone: +49.551.309.83.0 | Email: info@minebea-intec.com www.minebea-intec.com...

Table of Contents