DTC
Help Message
2568
TEMPERATURE CUTOUT ACTIVE - AMBIENT
TEMPERATURE TOO LOW
421
POWER MODULE TOO HOT - PLEASE WAIT
4235
POWER MODULE TOO HOT - REDUCED OPER-
ATION
4236
POWER MODULE TOO COLD - MODULE SHUT-
DOWN
426
MASTER MODULE TEMPERATURE – OUT OF
RANGE
6-26
Flash
Alarm
Code
If TransportMode
= TRUE PF: Con-
tinuous
2_5
• Drive and Lift Restrictions
If TransportMode
= FALSE PF: OFF
• DriveState = PREVENTED
None
4_2
• LiftUpState = PREVENTED
• DriveState =CREEP
None
4_2
• LiftUpState = CREEP
• DriveState = PREVENTED
None
4_2
• LiftUpState = PREVENTED
None
4_2
• Normal operation
Action
• The temperature as communicated by the temperature sensor
located on the temperature/tilt sensor is less than or equal to {PER-
SONALITIES->TEMP CUTOUT->CUTOUT SET}
• (See Low Temperature Cutout Functionality)
• This DTC shall not be displayed in GroundMode, and no restrictions
shall be implemented.
• Heatsink temperature above 203°F (95° C).
• Possible Cause:
• Controller is operating in an extreme environment.
• Excessive load on vehicle.
• Improper mounting of controller
• Heatsink temperature exceeded 185° F (85° C).
• Effect: Reduced drive and brake torque.
• Possible Cause:
• Controller is performance-limited at this temperature.
• Controller is operating in an extreme environment.
• Excessive load on vehicle
• Improper mounting of controller.
• Heatsink temperature below -40° F(-40°C).
• Possible Cause:
• Controller is operating in an extreme environment.
• The Ground Module's internal temperature sensor is out of range. (<
104° F (40° C) or > 302° F (150° C)