JLG R1532i Operation And Safety Manual page 100

Hide thumbs Also See for R1532i:
Table of Contents

Advertisement

SECTION 6 - GENERAL SPECIFICATIONS AND MAINTENANCE
DTC
Help Message
4475
POWER MODULE - BDI FAULT
4476
BATTERY VOLTAGE TOO HIGH – UNPLUG
CHARGER
4477
BATTERY VOLTAGE TOO HIGH – FORCING DIS-
CHARGE
6-28
Flash
Alarm
Code
• DriveState = PREVENTED
None
4_4
• LiftUpState = PREVENTED
• Enter SafeMode
None
4_4
• LiftDownState = MAX
Lift Down = PREVENTED
None
4_4
Lift Up = PREVENTED
Drive = PREVENTED
Action
• Pump BDI Fault Set: BDI Percentage charge at 0% when the pump
was activated.
• Effect: ShutdownPump
• Possible Cause:
• Battery is fully discharged
• BDI parameters are mis-tuned
• The Ground Module momentarily measured excessively high battery
voltage (VBAT) (>32.0V) and entered SafeMode to protect system
devices. This may be due to improper battery charging or incorrect
voltage batteries being used.
• The Ground Module momentarily measured excessively high battery
voltage (VBAT) (>32.0V) and entered SafeMode. This may be due to
improper battery charging or incorrect voltage batteries being used.
Trigger
31215087

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1932iR1932Pvc 1910

Table of Contents