Cordless angle nutrunner

Advertisement

Quick Links

Model
EABA 15-900
EABA 26-560
EABA 32-410
EABA 45-330
EABA 50-450
EABA 60-370
EABA 75-300
EABA 95-240
Download the latest version of this document at
http://www.desouttertools.com/info/6159929390_EN
Read all safety warnings and instructions
Failure to follow the safety warnings and instructions may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference
Cordless Angle Nutrunner
Product Instructions
Part number
6151659610
6151659620
6151659630
6151659640
6151659650
6151659660
6151659670
6151659680
WARNING
Printed Matter No. 6159929390_EN
Issue No.
01
Date
06/2020
Page
1 / 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EABA 15-900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Desoutter EABA 15-900

  • Page 1 Printed Matter No. 6159929390_EN Issue No. Date 06/2020 Page 1 / 24 Cordless Angle Nutrunner Product Instructions Model Part number EABA 15-900 6151659610 EABA 26-560 6151659620 EABA 32-410 6151659630 EABA 45-330 6151659640 EABA 50-450 6151659650 EABA 60-370 6151659660 EABA 75-300...
  • Page 2: Table Of Contents

    Table of Contents Product Information .......................... 3 General Information......................... 3 Warranty.......................... 3 Website .......................... 3 Information about spare parts .................... 3 Dimensions (mm) ......................... 3 CAD files .......................... 4 Overview ............................ 4 General overview ......................... 4 Product description ...................... 4 Technical data........................ 5 Accessories.......................... 6 Installation.............................. 7 Installation Instructions........................ 7 Inserting the battery pack..................... 7 How to connect the tool to CVIMONITOR................ 7 How to install optional accessories .................. 7 Operation.............................. 8...
  • Page 3: Product Information

    • The product warranty relies on the correct use, maintenance, and repair of the tool and its component parts. • Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Desoutter or their Certified Service Partners during the warranty period is not covered by the warranty.
  • Page 4: Cad Files

    General overview EABA tools are cordless angle-head nutrunners. They are hand-held by the operator and powered by a Desoutter battery pack. On delivery, the tool display is protected by a password. Tools are delivered with 6 Psets which are configurable from the tool display or from CVI CONFIG.
  • Page 5: Technical Data

    Product Information Trigger Battery footprint Display Programming buttons Reverse button Technical data Voltage (V) 36 V Output drive Model Type EABx 15-900 Sq. 1/4" EABx 26-560 Sq. 3/8" EABx 32-410 Sq. 3/8" EABx 45-330 Sq. 3/8" EABx 50-450 Sq. 3/8" EABx 60-370 Sq.
  • Page 6: Accessories

    Product Information Rated speed (rpm) Model EABx15-900 EABx 26-560 EABx 32-410 EABx 45-330 EABx 50-450 EABx 60-370 EABx 75-300 EABx 95-240 EABx stands for EAB/EABA/EABC. Weight Model (kg) (lb) EABx 15-900 1.55 3.42 EABx 26-560 1.65 3.64 EABx 32-410 1.65 3.64 EABx 45-330 1.76...
  • Page 7: Installation

    Installation Installation Installation Instructions Inserting the battery pack Insert the battery pack in front or behind the tool until a locking sound can be clearly heard. There is no ON/OFF switch: the tool is ready to operate as soon as a battery pack is mounted. When the tool is powered on, tool LEDs are blinking.
  • Page 8: Operation

    Operation Operation Configuration Instructions How to configure the tool Icons and buttons The password is enabled. The password is disabled. Press the button "Validate/Run reverse". Press the right button. Press the left button. "Validate/Run reverse" button Right button Left button Validate Save Quit...
  • Page 9 Operation Press this button during 2 seconds. Press this button to reach Configuration. Go to Enter password, then Pset password, use the buttons to display "1", save and and validate. The red padlock turns green. The procedure is the same to disable the Maintenance password. How to set up new passwords To set new passwords, current passwords must be disabled and the green padlock displayed.
  • Page 10 Operation • in.lb • kg.m • kg.cm • oz.in • dNm To change the torque unit, go to the main screen. Press this button during 2 seconds. Press this button to reach Configuration. Go to Torque unit, use the buttons to select the torque unit and validate. How to set up the reverse mode Go to the main screen.
  • Page 11: Operating Instructions

    Operation Parameter Description Start torque This is the torque value that must be reached to declare the Pset as started. Below this value, neither result or report will be generated. Angle threshold This is the torque threshold value used to start counting the angle.
  • Page 12 Operation Go to Enable, tick the box to enable this Pset, save and validate. Starting the tool Fit the tool with a suitable socket. Select the appropriate Pset. Hold the tool by means of the handle and apply to the fastener to be tightened. WARNING Risk Of Injury As the reaction force increases in proportion to the tightening torque, there is a risk of severe bodily injury of the operator as a result of unexpected behavior of the tool.
  • Page 13 Operation Angle control with torque monitoring Abort torque Max. torque Min. torque Angle threshold Pset start torque Min. angle Target angle Max. angle For tools running in severe applications, it may happen that reports are null when the battery is low. Reporting LEDs Green Yellow...
  • Page 14: Results Monitoring

    Operation LED color Description Action to do Yellow Incomplete rundown Tighten again. Yellow and red (orange) Reject report Loosen and tighten again. Above max. limits Remove and replace the fastener. How to reverse the rotation Run reverse button Press this button. Red and green LEDs are blinking alternatively.
  • Page 15: Results Collection And Analysis

    Operation Launch CVI MONITOR to collect and display the last 100 results. Refer to the user manual of CVIMONITOR available at https://www.desouttertools.com/resource-centre. Results collection and analysis Connect the tool to a PC by using the eDOCK device. Launch CVI ANALYZER to collect and display the last 1000 results. CVI ANALYZER CVI ANALYZER is intended to analyze and import/export tightening data with results, curves, filters, profiles.
  • Page 16: Service

    Service Service Firmware version on tool display The firmware version of the tool is displayed in the menu "Maintenance/Tool". AX.YY.ZZ. Tool information from tool display Go to "Maintenance/Tool" menu to get the following information: Total counter Number of tightenings since the manufacturing of the tool. Battery The current voltage value is displayed.
  • Page 17: Instructions For Transducerized Tools

    Service Right hand thread When reassembling: Apply the recommended glue. Tighten to the required torque. Lubricate with the required grease or oil. Do not apply too much grease on gears or bearings; a thin coat shall be sufficient. Instructions for transducerized tools •...
  • Page 18: Calibration Via Tool Display

    This function is set in the "Maintenance" menu. Enter the Maintenance password in the "Configuration" menu. Insert a torque transducer in line with the tool and connect it to any measuring unit from the Desoutter range. Go to "Maintenance/Calibration". Select the number of tightenings required to execute the calibration and press OK.
  • Page 19: Motor Align

    It is mandatory to calibrate the tool equipped with the fixed accessory before use. Upgrading tool firmware Click this icon. Click Upgrade tool firmware. Contact your Desoutter representative to get the last firmware version. Follow the instructions on screen. 06/2020 19 / 24...
  • Page 20: Troubleshooting

    1- The tool tightening counter has been reached. I038 Tool logs 1- Unexpected tool software exception. 2- Log file has been generated by the tool. 3- Contact your Desoutter representative for support. I046 Abnormal battery current 1- Abnormal battery current consumption. Check the Pset settings.
  • Page 21 2- Check the tool cable is not damaged. W212 Result not stored 1- It is not possible to store the tightening result in the system. 2- Contact your Desoutter representative for support. W216 Current high 1- Maximum current exceeded. 2- Contact your Desoutter representative for support.
  • Page 22 Procedure E223 Drive init error 1- Software failure. 2- Restart the system. 3- If the problem occurs again, contact your Desoutter representative for support. E227 Motor stalled 1- Motor stalled (could be missing phase, wrong motor tune or power electronics failure) 2- Try once again.
  • Page 24 Original instructions Founded in 1914 and headquartered in France, Desoutter Industrial Tools is a global leader in electric and pneumatic assembly tools serving a wide range of assembly and manufacturing operations, including Aerospace, Automotive, Light and Heavy Vehicles, Off-Road, General Industry.

Table of Contents