Copper Ethernet Ports - Siemens SIMATIC NET RUGGEDCOM RSG2200F Installation Manual

Rugged
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2200F:
Table of Contents

Advertisement

Communication Ports
4.1 Copper Ethernet Ports
1
Figure 4.2
4.1

Copper Ethernet Ports

The RUGGEDCOM RSG2200F supports several 10/100/1000Base-TX Ethernet ports
that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP)
cables with either RJ45 male connectors. The RJ45 connectors are directly connected
to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP)
cables.
Electric shock hazard – risk of serious personal injury and/or equipment inter-
ference
If shielded cables are used, make sure the shielded cables do not form a ground loop
via the shield wire and the RJ45 receptacles at either end. Ground loops can cause
excessive noise and interference, but more importantly, create a potential shock
hazard that can result in serious injury.
Pin-Out
The following is the pin-out description for the RJ45 connectors:
8
Figure 4.3
24
1
Port LED
Port LEDs
WARNING
1
RJ45 Ethernet Port Pin Configuration
Pin
10/100Base-TX
1
RX+
2
RX-
 
LED State
Yellow (Solid)
Yellow (Blinking)
Off
Name
1000Base-TX
BI_DA+
BI_DA-
Description
Link established
Link activity
No link detected
Description
Receive Data+ or Bi-
Directional Pair A+
Receive Data- or Bi-
Directional Pair A-
RUGGEDCOM RSG2200F
Installation Manual, 01/2020, C79000-G8976-1346-06

Advertisement

Table of Contents
loading

Table of Contents