  • Page 1 OWNER’S MANUAL...
  • Page 3 MAINTENANCE pg 029 DISASSEMBLY AND STORAGE pg 031 TROUBLESHOOTING pg 033 ERROR CODES pg 034 VISIT BESTWAY YOUTUBE CHANNEL FOR INSTRUCTION VIDEOS WE SUGGEST NOT TO RETURN PLEASE VISIT: THE PRODUCT TO THE STORE QUESTIONS? PROBLEMS? MISSING PARTS? BESTWAYCORP.COM/SUPPORT For FAQ, Manuals, Videos Or spare Parts, Please Visit bestwaycorp.com/support...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS Carefully read, understand, and follow all information in this user manual before installing and using the spa. IMPORTANT SAFETY INSTRUCTIONS - READ AND FOLLOW ALL INSTRUCTIONS. WARNING: • The spa must be supplied through an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA.
  • Page 5 CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
  • Page 6 in such case, please unplug and stop using the spa at once. Don’t reset the product by yourself. And you must contact the local service agent to check and repair the product. • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...
  • Page 7 broken or missing. Never attempt to replace the inlet / outlet pipes. Always consult your local Aftersales centre. • RISK OF ELECTRIC SHOCK. Install at least 2m from all metal surfaces. • RISK OF ELECTRIC SHOCK. Never operate any electrical appliance when in your spa or when your body is wet.
  • Page 8 • The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level that is several degrees above the normal body temperature of 37°C (98.6°F). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting.
  • Page 9 aids, but they are not substitutes for continuous and competent adult supervision. Safety equipment - It is recommended to keep rescue equipment (e.g. a ring buoy) by the spa (if appropriate). - Keep a working phone and a list of emergency phone numbers near the spa.
  • Page 10 NOTE: • Please examine equipment before use. Notify Bestway at the customer service address listed on this manual for any damaged or missing parts at the time of purchase. Verify that the equipment components represent the models that you had intended to purchase.
  • Page 11 SELECTED LOCATION Indoor and outdoor & above ground & portable wiring & portable spa WARNING: The selected location has to be able to support of supporting the expected load. WARNING: An adequate drainage system has to be provided to deal with overflow water for both indoor and outdoor installations.
  • Page 12 package. • Please keep at least 1m clearance around the spa. • Consult your local government authority for water regulations related to convenient water supply for filling the spa. • Recommended to consult experts and/or local authorities to apply local or national laws/regulations relating to childproof fencing, safety barriers, lighting, and other safety requirements.
  • Page 13 these effects it is best to provide plenty of ventilation to the selected area. An architect can help determine if more ventilation is needed. • Consult your local government authority for installation regulations. • Keep suitable air treatment in the spa chamber (ventilation and dehumidification) regularly to preserve the bathers’...
  • Page 14 PRE-SETUP CHECK LIST PARTS CHECKS Please examine equipment before use. Notify Bestway customer service of any ® damaged or missing parts at the time of purchase. Verify that the equipment components represent the model that you had intended to purchase. For reference please use the diagrams below.
  • Page 15 CANCUN AIRJET S100102 (60003) — 1.80 m x 66 cm / 71" x 26" 2 - 4 1.5-2ºC/h 1,325 L/h 0.8PSI 669 L 696 kg 3-4ºF/h 350 gal/h 0.055Bar 177 gal 1,534 Lb P05137 P05328 P05161 04 54123GASS17 P6931ASS16 P05343 P05345 P6575ASS16 P05347...
  • Page 16 TAHITI AIRJET S100102 (60007) — 1.80 m x 66 cm / 71" x 26" 2 - 4 1.5-2ºC/h 1,325 L/h 0.8PSI 669 L 696 kg 3-4ºF/h 350 gal/h 0.055Bar 177 gal 1,534 Lb P05143 P05328 P05165 04 54123GASS17 P6931ASS16 P05343 P05345 P6575ASS16 P05347...
  • Page 17 VEGAS AIRJET S100102 (60011) — 1.96 m x 61 cm / 77" x 24" 4 - 6 1.5-2ºC/h 1,325 L/h 0.8PSI 775 L 744 kg 3-4ºF/h 350 gal/h 0.055Bar 205 gal 1,640 Lb P05152 P05328 P05171 04 54112GASS15 P05172 P6931ASS16 P05343 P05345 P6575ASS16...
  • Page 18 IBIZA AIRJET S100102 (60015) — 1.80 m x 1.80 m x 66 cm / 71" x 71" x 26" 4 - 6 1.5-2ºC/h 1,325 L/h 0.8PSI 778 L 807 kg 3-4ºF/h 350 gal/h 0.055Bar 205 gal 1,779 Lb P05156 P05328 P05178 P04125 P6931ASS16...
  • Page 19 HONOLULU AIRJET S100102 (60019) — 1.96 m x 71 cm / 77" x 28" 4 - 6 1.5-2ºC/h 1,325 L/h 1.2PSI 916 L 954 kg 3-4ºF/h 350 gal/h 0.08Bar 242 gal 2,103 Lb P05190 P05328 P05194 04 54174GASS18 P05341 P05343 P05345 P6575ASS16 P05347...
  • Page 20 ST. MORITZ AIRJET S100102 (60023) — 2.16 m x 71 cm / 85" x 28" 5 - 7 1-1.5ºC/h 1,325 L/h 1.2PSI 1190 L 1210 kg 2-3ºF/h 350 gal/h 0.08Bar 314 gal 2,668 Lb P05196 P05328 P05200 04 54175GASS18 P05341 P05343 P05345 P6575ASS16...
  • Page 21 ST. LUCIA AIRJET S100102 (60037) — 1.70 m x 66 cm / 67" x 26" 2 - 3 1.5-2ºC/h 1,325 L/h 0.8PSI 605 L 630 kg 3-4ºF/h 350 gal/h 0.055Bar 160 gal 1,389 Lb P05271 P05328 P05272 P05091 P6931ASS16 P05343 P05345 P6575ASS16 P05347...
  • Page 22 INSTALLATION < 10°C(50°F) SET-UP INSTRUCTION IN WINTER > 15°C(59°F) > 15°C(59°F) It is important to follow these suggestions if you are setting up the spa during the winter period. This will prevent damage to the PVC material and extend the life of your product drastically.
  • Page 23 5 min HELSINKI 0.48-0.69Bar 7-10PSI 5 min PARIS BALI...
  • Page 24 PRCD Test RESET RESET RESET RESET TEST TEST TEST TEST NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to scale. 1. Insert the plug. 2. Press the “RESET” button, the indicator light turns on. 3. Press the “TEST” button, the indicator light turns off. 4.
  • Page 25 SPA PUMP EQUIPOTENTIAL BONDING TERMINAL It is recommended to arrange for a qualified electrician to connect the spa pump to an equipotential bonding terminal using a minimum 2.5mm solid copper conductor. When inflating, you will notice that air will be expelled from the area where the air hose connects to the pump, this is normal for technique requirements.
  • Page 26 USING THE SPA A. LOCK/UNLOCK BUTTON: The pump has a 5-minute auto-lock, this light will turn on. To lock or unlock the pump, place a finger over the lock/unlock button for 3 seconds. B. POWER-SAVING TIMER BUTTON: Designed to help avoid wasting power by setting the time and duration of the heating cycle for the spa.
  • Page 27 attached. Air can accumulate inside the spa and cause irreparable damage to the cover and bodily harm. NOTE: Heat and massage system work together to create a warm massage experience. E/G. TEMPERATURE ADJUSTMENT BUTTONS: Pressing the Temperature Increase or Decrease buttons will cause the LED to flash. When it is flashing you can adjust to the desired temperature setting.
  • Page 28 be on. In this mode, the Freeze Shield™ system can keep the internal temperature between 6°C(42.8°F) and 10°C(50°F) to prevent damage, such as water freezing in the pipes or the circulation system. Important: If the Freeze Shield™ system isn’t working, alarms will pop up on the spa. Be sure to check the status of your spa if the outdoor temperature is below 6°C(42.8°F).
  • Page 29 MAINTENANCE CAUTION: You must ensure the pump is unplugged before beginning spa maintenance to avoid risk of injury or death. Adding Air: Your spa will require additional air to be added from time to time. Changes in temperature from day to night will change the pressure in the spa and may cause a certain amount of deflation.
  • Page 30 Water quality will be directly related to frequency of use, number of users and overall maintenance of the spa. The water should be changed every 3 days if there is no chemical treatment being performed with the water. It is highly recommended to use tap water for spa filling to minimize the influence of unwanted content, such as minerals.
  • Page 31 DISASSEMBLY AND STORAGE DRAINING THE SPA P05347 NOTE: Dry the spa pool. For Paris and Bali Spas: You may find steam inside the air chamber, and mold may appear after storage if there is water inside. Please unscrew the valve and use the pipe to blow into the air chamber until you dry all the steam inside.
  • Page 32 Make sure the spa and pump are completely dry. This is essential to extend the life of the spa. We recommend using the pump to blow dry the spa, pump and pipes. Remove the filter sets and discard the used filter cartridges. Re-attach the two stopper caps onto the spa’s inlet and outlet valves.
  • Page 33 Bestway strives to provide the most trouble-free spas on the market. If you experience any problems whatsoever, do not hesitate to contact Bestway or your authorized dealer. Here are some helpful tips to help you to diagnose and rectify some common sources of trouble.
  • Page 34 ERROR CODES CAUSES REASONS SOLUTIONS The water flow sensors work 1. The water flow sensor flags didn’t fall back into the 1. Unplug the plug gently, strike the side of the pump but not violently, and plug it without pressing the filter or heat correct position.
  • Page 36 Bestway Central & South America Ltda, Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, Unit 2/98-104 Carnarvon St Silverwater, NSW 2128, Australia Tel: Australia: (+61) 29 0371 388; New Zealand: 0800 142 101 Exported by/Exporté...