Technical Specifications
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
When determining cable lengths, make sure the minimum input voltage for the pow-
er supply is provided at the power source.
Power Sup-
a
Power consumption varies based on the device configuration. A typical RUGGEDCOM RX1511 chassis
will consume approximately 35 W of power.
b
(T) denotes time-delay fuse.
5.2
Failsafe Relay Specifications
Maximum Switching Voltage
a
Inductive load R/L = 7 ms
b
Resistive load
RUGGEDCOM RX1511
Installation Manual, 12/2019, C79000-G8976-1056-16
Input Range
ply Type
Min
88 VDC
HI
85 VAC
88 VDC
HIP
85 VAC
24
13 VDC
24P
48
36 VDC
48P
12
9 VDC
12P
30 VDC
125 VDC
250 VAC
Internal
Fuse Rating
Max
300 VDC
3.15 A(T)
264 VAC
300 VDC
3.15 A(T)
264 VAC
b
36 VDC
10 A(T)
72 VDC
3.15 A(T)
15 VDC
12 A
Rated Switching Current
5 A
a
b
0.1 A
, 0.15 A
6.25 A
Maximum
Power Con-
Insulation
a
sumption
b
65 W
2800 VDC
for 1 minute
b
65 W
63.5 W
1500 VDC
for 1 minute
b
60 W
1500 VAC or
67 W
2121 VDC
for 1 minute
Isolation
2800 VDC for 1 minute be-
tween coil and contacts
5
43