Page 2
Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet switches RUGGEDCOM RS969 Communication Ports Technical Specifications Equipment Manual Accessories Certification 10/2023 C79000-G8976-1038-05...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer's exposure to cyber threats.
SIMATIC NET glossary The SIMATIC NET glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Registered trademarks The following and possibly other names not identified by the registered trademark sign ®...
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile app Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
Introduction The RUGGEDCOM RS969 is an industrially hardened, fully managed Ethernet switch providing dual fiber optical Fast Ethernet or Gigabit ports and eight Fast Ethernet copper ports. Designed to operate reliably in harsh industrial environments the RUGGEDCOM RS969 provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations, factory floors or in curb side traffic control cabinets.
Introduction 1.2 Description • Universal high-voltage range: 88-300 VDC or 85-264 VAC. • Popular low-voltage DC ranges: 12, 24, 48 VDC • Dual redundant, parallel load-sharing power supplies (option) • Can be powered from different sources for ultimate redundancy • Available with M12 (Mini-Change) or M23 style connectors •...
Page 12
Introduction 1.2 Description Copper Ethernet Ports Port Status LED POWER 1 LED POWER 2 LED ALARM LED RS-232 Console Port Failsafe Output Relay M12 Power Supply Port Fiber Optic Ethernet Ports RUGGEDCOM RS969 Equipment Manual, 10/2023, C79000-G8976-1038-05...
Page 13
Introduction 1.2 Description Surge Ground Connection Chassis Ground Connection Figure 1.1 RUGGEDCOM RS969 (M12 Connectors Shown) Copper Ethernet Ports Port Status LED POWER 1 LED RUGGEDCOM RS969 Equipment Manual, 10/2023, C79000-G8976-1038-05...
Introduction 1.3 Required Tools and Materials POWER 2 LED ALARM LED RS-232 Console Port Failsafe Output Relay M23 Power Supply Port Fiber Optic Ethernet Ports Surge Ground Connection Chassis Ground Connection Figure 1.2 RUGGEDCOM RS969 (RJ45 Connectors Shown) Port Status LED Indicate the status of each port. State Description Yellow (Solid)
Siemens recommends using RUGGEDCOM industrial Ethernet shielded cables for all Ethernet ports. Siemens does not recommend the use of copper cabling of any length for critical, real-time substation automation applications. All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards.
Introduction 1.5.1 Supported fiber optic cables Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Installing the Device 2.3 Mounting the Device Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RS969 is designed to be mounted on a panel by affixing the top and bottom flanges of the device to a panel using screws.
Installing the Device 2.4 Connecting the Failsafe Alarm Relay Flange Figure 2.1 Panel Mounting (Typical) Install the supplied screws to secure the flanges to the panel. Connecting the Failsafe Alarm Relay The Failsafe output relay is provided to signal critical error conditions that may occur on the RUGGEDCOM RS969 series switches.
Installing the Device 2.5 Connecting Power The proper relay connections are as follows: Description Normally Closed Common Normally Open Figure 2.2 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS969 is equipped with either a Mini or M23 A-coded male power supply input connector.
Page 23
Installing the Device 2.5.1 Power Supply Connector Pin-Out Terminal # Description Usage PS1 Live/+ PS1 Live/+ is connected to the positive (+) terminal if the power source is DC or to the (Live) terminal if the power source is AC. Chassis Ground Chassis Ground is connected to the Safety Ground terminal for AC inputs or the equipment ground bus for DC inputs.
Installing the Device 2.5.2 Power Supply Wiring 2.5.2 Power Supply Wiring The following illustrates how to connect the RUGGEDCOM RS969 to a single or dual power supplies. Note • For 100-240 VAC rated equipment, a 250 VAC appropriately rated circuit breaker must be installed.
Page 25
Installing the Device 2.5.2 Power Supply Wiring M23 Power Connector Neutral Safety Line 250 VAC Breaker 110/230 VAC Power Source Safety Earth Figure 2.6 AC Power Supply Wiring Example (M23 Power Connector) Single Low DC Power Supply Wiring Mini Power Connector Ground Bus 300 VDC Breaker DC Power Source Figure 2.7...
Page 26
Installing the Device 2.5.2 Power Supply Wiring M23 Power Connector Ground Bus 300 VDC Breaker DC Power Source Figure 2.8 DC Power Supply Wiring Example (M23 Connector) Dual AC/DC Power Supply Wiring (M23 Connector Only) M23 Power Connector Ground Bus Line 250 VAC Breaker Neutral 110/230 VAC Power Source (PS2) 110/230 VAC Power Source (PS1)
Page 27
Installing the Device 2.5.2 Power Supply Wiring M23 Power Connector Ground Bus Line 250 VAC Breaker 110/230 VAC Power Source (PS2) Neutral Safety 300 VDC Breaker DC Power Source (PS1) Figure 2.10 AC and DC Power Supply Wiring Example M23 Power Connector Ground Bus 300 VDC Breaker DC Power Source (PS2)
Installing the Device 2.5.3 Disabling Line-to-Ground Transient Protection 2.5.3 Disabling Line-to-Ground Transient Protection All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where users require the inputs to be isolated from ground, remove the ground braid between Surge and Chassis Ground. All line-to-ground transient protection circuitry will be disabled.
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS969 console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM RS969 Configuration Manual"...
Device Management 3.2 Configuring the Device device's IP address. The factory default IP address for the RUGGEDCOM RS969 is https://192.168.0.1. For more information about available ports, refer to "Communication Ports" (Page 23). Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM RS969 interface.
Communication Ports The RUGGEDCOM RS969 can be equipped with various types of communication ports to enhance its abilities and performance. To determine which ports are equipped on the device, refer to the factory data file available through RUGGEDCOM RS969. For more information on how to access the factory data file, refer to the "RUGGEDCOM RS969 User Guide"...
Communication Ports 4.2 Fiber Optic Ethernet Ports Pin-Out (RJ45) The following is the pin-out description for the RJ45 connectors: 10/100Base- Description TX Signal Receive Data+ Receive Data- Transmit Data+ Figure 4.3 RJ45 Ethernet Port Pin Reserved (Do Not Connect) Configuration Reserved (Do Not Connect) Transmit Data- Reserved (Do Not Connect) Reserved (Do Not Connect)
Page 35
Communication Ports 4.2 Fiber Optic Ethernet Ports Rx Connector Figure 4.5 LC Port For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications" (Page 28). RUGGEDCOM RS969 Equipment Manual, 10/2023, C79000-G8976-1038-05...
Technical Specifications This section details the specifications and operating conditions of the device. General specifications Insulation Class I Overvoltage category OVC II Power Supply Specifications Power Minimum Maximum Internal Isolation Maximum Supply Type Input Input Fuse Rating Power Consumption 12–24 VDC 10 VDC 36 VDC 3.15A (T)
All cabling is duplex type unless otherwise specified. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages. To convert from average to peak, add 3 dBm.
Technical Specifications 5.6 Operating Environment Operating Environment The RUGGEDCOM RS969 is rated to operate under the following environmental conditions. Ambient Operating -40 to 85° C (-40 to 185° F) Temperature Ambient Storage -40 to 85° C (-40 to 185° F) Temperature Ambient Relative 5% to 95% Humidity...
Accessories This chapter details the various accessories available for the RUGGEDCOM RS969. Power (1/unit) M23 Power Mating Connector • Description M23 5pin female connector, 600V, IP68 rated • Order Code 99-60-0007 Cable Specifications • 3/18 AWG, jacket OD range 0.20" - 0.48"...
Approvals This section details the standards to which the RUGGEDCOM RS969 complies. Note All relevant certificates and test reports are available on Siemens Industry Online Support [https://support.industry.siemens.com/cs/ww/en/ps/16008/cert]. 7.1.1 UKCA This device is certified for use in Great Britain and bears the United Kingdom Certified Assessed (UKCA) marking.
Certification 7.1.3 European Union (EU) 7.1.3 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 7.1.6 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) This device further complies with IC RSS-210 and is approved under the ID 4997A- VG5RW80G.
Support at https://support.industry.siemens.com/cs/ww/en/view/89855782. 7.1.9 RoHS This device is declared by Siemens Canada Ltd. to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: EU RoHS Directives (EU) 2011/65 and (EU) 2015/863 •...
Certification 7.2 MIL-STD Test Specifications MIL-STD Test Specifications Test Description MIL-STD-167 Vibration Navy MIL-STD –167-1 Type I MIL-STD-461E CE101 CE102 DC 28V AC 115V RE101 RE102 RE102-1, Surface Ship Applications RE102-2, Submarine Applications, Internal RE102-3, AirCraft and Space Applications RE102-4, Ground Applications CS101 CS114 CS115...
Page 55
Certification 7.3 EMC and Environmental Type Tests IEC 61850-3 Type Tests Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure ± 8 kV Contact Enclosure Air ± 15 kV IEC 61000-4-3 Radiated RFI Enclosure ports 20 V/m IEC 61000-4-4 Burst (Fast Signal ports ±...
Page 56
Certification 7.3 EMC and Environmental Type Tests Test Description Test Levels Severity Levels AC Power ports 5 kV — IEEE 1613 Type Tests Note • If the unit contains copper ports, the IEEE 1613 conformance is Class 1 (during disturbance, errors may occur but recovery is automatic). •...
Page 57
Certification 7.3 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-30 Humidity (Damp Test Db 95% (non- — Heat, Cyclic) condensing), 55 °C (131 °F), 6 cycles IEC 60255-21-1 Vibration 2g @ 10-150 Hz Class 2 IEC 60255-21-2 Shock 30 g @ 11 ms Class 2...
Need help?
Do you have a question about the SIMATIC NET RUGGEDCOM RS969 and is the answer not in the manual?
Questions and answers