Siemens SIMATIC NET RUGGEDCOM RX1511 Installation Manual page 61

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1511:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
Environmental Type Tests
52
Description
ESD
Test
IEC 60068-2-1
Cold Temperature
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
Enclosure Contact
Enclosure Air
Description
Test Ad
Dry Heat
Test Bd
Humidity (Damp
Test Db
Heat, Cyclic)
Vibration
Shock
Bump
Seismic
Test Levels
± 8 kV
± 15 kV
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10-150 Hz
30 g @ 11 ms
10 g @ 16 ms
Method A
RUGGEDCOM RX1511
Installation Manual, 12/2019, C79000-G8976-1056-16
Severity
Levels
 
 
 
Class 2
Class 2
Class 1
Level 2