ZCVRB60 -Mantel Clearances –Unvented Chase- Ventilation Plates In Place -As Shipped
Before installing any mantels it is
important to determine the
combustibility of its material(s). There
are two types of mantels to consider:
Combustible and Non-Combustible.
A Combustible Mantel is one that
consists of material(s) that may
discolor, combust, or lose its integrity
in the presence of heat. These types
of mantels must strictly conform to the
dimensional requirements shown.
Conversely, a Non-Combustible
Mantel is one that is constructed with
material(s) that will not combust.
Check your local codes and
regulations to determine whether your
mantel is Combustible or Non-
Combustible.
The advantage to Non-Combustible
Mantels is that it may extend right up
to the tile lip of the fireplace.
Combustible mantels must adhere to
the dimensional restrictions shown.
-Combustible Objects on Non-
Combustible Mantel Warning-
Combustible objects must not be placed
on a Non-combustible Mantel unless the
mantel meets the dimensional
requirements for a Combustible Mantel.
Determine whether your mantel
conforms to the requirements of a
Combustible Mantel.
Adjacent Wall
Mantel Dimensions are from front
face or Non-Combustible Facing
Materials covering fireplace.
Combustible
Mantel Line
9-9/16"
Combustible Hearth
is allowed below
opening of appliance
Mantel Leg Clearances
Header
Height is
29-1/2"
39-3/4"
Tile Lip / Top
of Opening
Top View
Adjacent Wall
76"
Minimum
Enclosure
Height