Fan Cowl; External Fan Made Of Metal - Siemens SIMOTICS TN Series Operating & Installation Instructions Manual

Low-voltage motor n-compact
Table of Contents

Advertisement

Maintenance
9.2 Corrective Maintenance
9.2.4

Fan cowl

To remove or replace the external fan, the fan cowl must be disassembled. The fan cowl is
fixed on the machine enclosure with screws.
Disassembly
1. Secure the fan cowl against falling before you start working.
2. Loosen the fixing screws that secure the fan cowl on the enclosure.
3. Observe existing retaining components and retain them for the reassembly.
Assembly
Proceed in the reverse order to assemble the fan cowl.
1. Position the fan cowl and tighten the fixing screws.
2. Ensure that the retaining components are undamaged and correctly installed.
9.2.5

External fan made of metal

External metal fans have a keyway connection and are prevented from axially shifting using
a locking ring.
Disassembly
1. The external fan
2. Use a suitable device to pull off the external fan.
3. Avoid using a hammer.
4. Secure the parallel key from falling out or remove it.
110
is fixed on the shaft with a locking ring
Pliers according to DIN 5254 should preferably be used for this purpose.
Figure 9-1
Ventilation (schematic diagram with axial fan)
. Remove the locking ring.
SIMOTICS TN Series N-compact 1LL8
Operating Instructions 11/2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics tn 1ll8

Table of Contents