Operation On A Converter With A Low Pulse Frequency - Siemens SIMOTICS TN Series Operating & Installation Instructions Manual

Low-voltage motor n-compact
Table of Contents

Advertisement

Converter operation
● If the design of the motor requires connection to a particular converter type, the rating plate
● The converter is correctly parameterized. The parameterization data is specified on the
● Any supplementary motor monitoring devices and equipment have been correctly
● In continuous operation, the motor cannot exceed the specified upper speed limit n
7.2.1

Operation on a converter with a low pulse frequency

NOTICE
Increased motor temperature
If the pulse frequency is less than the rated pulse frequency, then increased motor losses
occur. This results in a higher motor temperature.
● Reduce the power to prevent exceeding the temperature class and to avoid consequential
● Contact the Service Center if necessary.
Dangerous voltage via the converter
As long as the feeding converter is switched on, or the DC link of the converter is not
discharged, there can be a voltage at the motor terminals even when the rotor is not moving.
The voltage is up to 1000 V, depending on the converter type.
Ensure that the five safety rules (Page 15) are followed before working on the motor.
● The bearing insulation should be implemented as shown on the plates.
SIMOTICS TN Series N-compact 1LL8
Operating Instructions 11/2018
will contain corresponding additional information.
rating plate of the machine. Information about the parameters is available in the operating
instructions for the converter.
connected and are functioning correctly.
undershoot the lower speed limit n
The permissible acceleration time to the limit speed n
assignment.
premature thermal aging of the insulation.
WARNING
.
min
depends on the parameter
min
Start-up
7.2 Converter operation
or
max
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics tn 1ll8

Table of Contents