Siemens SINUMERIK 840D sl OP 010 Manual page 51

Operator panel front
Table of Contents

Advertisement

● "Machine control panel address - MCP" (0-255)
This specifies the address of the associated MCP. It matches the [Station] mcpIndex setting
from config.ini.
● "Electronic key system index - EKS" (0-255)"
This specifies the index of the associated EKS. It matches the [Station] eksIndex setting
from config.ini.
● "Enable direct keys" (yes/no)
This specifies whether direct keys (if present) should communicate with the PLC (yes) or
be treated as ordinary keys (no).
"OK" saves any modified values to the config.ini file or to the Flashstore (HT 8 individual mode).
Parameters for the "config.ini" file
Two steps need to be performed:
1. Select "New" or "Replacement for existing panel".
2. Select what is to be replaced.
When an unknown TCU (i.e. not yet registered with the boot server) is started, a selection
menu containing both the "New" and "Replacement for existing panel" items will appear. The
accessibility of all the registered TCUs is tested in the background.
The status of this test process appears in the message line: "(0/3 panels inactive)".
Figure 1-17
Operator panel front: OP 010
Manual, 07/2018, A5E36371538B
TCU menu: New TCU
General information and networking
1.4 Networking
51