Networking; System Settings; Settings For Sinumerik Solution Line - Siemens SINUMERIK 840D sl OP 010 Manual

Operator panel front
Table of Contents

Advertisement

General information and networking

1.4 Networking

Unplugging the membrane connector
1. Loosen the dark clamping frame of the socket by pushing it up with your fingernails until it
engages in its upper, unlocked position (Fig. left).
2. Carefully pull off the membrane connector upward.
Plugging in the membrane connector
1. With the clamping frame in the upper position, carefully plug the membrane connector into
the socket.
2. Lock it in place by pushing down the clamping frame (Figure right).
1.4
Networking
1.4.1

System settings

1.4.1.1

Settings for SINUMERIK solution line

Range of validity
This description is valid for:
● NCU 7x0.3 PN with NCU-Basesoftware (Linux-based)
● PCU 50.5 with PCU-Basesoftware (Windows XP, Windows 7)
Introduction
This manual describes the structure and commissioning of the system network with
SINUMERIK solution line control and operator components with Ethernet-based
communication. The fundamentals of the system network are described first, details and
special cases are described in subsequent chapters.
Fundamentals
The system network for SINUMERIK solution line is structured as a star topology with a central
Ethernet switch, to which all Ethernet-based components of the system are connected.
For an NCU the connection is executed via the X120 Ethernet socket, for PCU it is executed
via the "Ethernet 2" connection. There is no default for all other components with two Ethernet
connections. These components have an internal 2-port switch and may be used to connect
an additional operator component. Thus in this case there can be deviation from the strict star
topology.
36
Operator panel front: OP 010
Manual, 07/2018, A5E36371538B