Daikin 4MXS100EV2C Service Manual page 25

Removal procedure, 8.0/8.5/10.0 kw class 32000 btu/h class, outdoor unit, inverter, multi type, heat pump

Advertisement

Si12-995
Step
5
Disconnect the
connectors.
Remove the main PCB.
6
2. Remove the reactor.
1
Remove the screw.
Remove the 3 screws
2
and lift the reactor
upward to remove it.
Removal Procedure
Procedure
V(yellow)
U(red)
[HR2](blue)
[HR1](white)
W(blue)
[S51]
[S101]
[S10]
[AC2]
(blue)
[AC1]
(brown)
(R10407)
(R10408)
Reactor
(R10409)
(R6434)
Removal of PCBs
Points
[S51] [S101] : service monitor
PCB
[S10] : terminal board
(transmission)
[HR1] [HR2] : reactor
[AC1] [AC2] : terminal board
(power supply)
[U] [V] [W] : compressor