Daikin 4MXS100EV2C Service Manual page 19

Removal procedure, 8.0/8.5/10.0 kw class 32000 btu/h class, outdoor unit, inverter, multi type, heat pump

Advertisement

Si12-995
Step
4
Disconnect the
connector for the four
way valve coil [S80].
5
Disconnect the
connectors for the
electronic expansion
valve coil.
[S20] (white): room A
[S21] (red): room B
[S22] (blue): room C
[S23] (yellow): room D
6
Disconnect the
connector for the liquid
pipe thermistor [S93].
Removal Procedure
Procedure
D
B
C
A
[S93]
Removal of Electrical Box
Pull out the clamp.
[S80]
Clamp
(R11187)
Pull out the clamp.
When reassembling, insert
each clamp into the small
hole.
For the electronic
expansion valve coil
Clamp
(R11188)
Pull out the clamp.
Clamp
(R10400)
Points
[S93]
(R17266)
17