Removal of Electrical Box
Step
7
Disconnect the
connector for the gas
pipe thermistor [S92].
Disconnect the
8
connector for the
thermistors [S90].
9
The wire harness of the
thermistor is hooked
under the electrical box.
Unhook it and pull out
the clamp.
18
Procedure
Clamp
[S92]
Clamp
(R10537)
[S90]
(R10538)
Hook
Clamp
(R6420)
Si12-995
Points
Pull out the clamp.
When reassembling, insert
the clamp into the small
hole.
[S92]
(R17267)
Pull out the clamp.
When reassembling, insert
the clamp of the thermistor
ASSY into the hole as
below.
Thermistor ASSY
(R17142)
When reassembling, insert
the clamp into the small hole.
Fixing position for the
thermistor harness
Removal Procedure