Daikin 4MXS100EV2C Service Manual page 10

Removal procedure, 8.0/8.5/10.0 kw class 32000 btu/h class, outdoor unit, inverter, multi type, heat pump

Advertisement

Removal of Outer Panels
Step
3
Slide the discharge
grille downward to
unfasten the 2 hooks at
the top.
Remove the discharge
4
grille.
Remove the nut and
5
remove the outdoor fan.
8
Procedure
Hook
Outdoor fan
(R17173)
(R10380)
Nut size : M8
When reassembling, align
the
fan with the D-cut section of
(R10381)
the motor shaft.
Si12-995
Points
13 mm
(R12301)
mark of the outdoor