Wizards
4.1 Example wizard
10. Enter the correct pulses per revolution for the encoder.
11. Select the required macro source.
12. Set the minimum speed at which the attached motor
13. Set the ramp-up time in seconds.
14. Set the ramp-down time in seconds.
34
The information is normally printed on the casing of the
encoder.
See Basic commissioning with IOP (Page 32).
should run.
This is the time in which the motor will take to reach the
selected motor speed.
This is the time the motor will take from being given the
OFF1 command to reaching a standstill.