1-2-1. X/Y-scale, X/Y-offset

Touch the Scale Offset key (4) in the sewing operation screen to display the X/Y-scale and X/Y-offset setting
screen.
Use when you would like to enlarge, reduce or move the pattern without changing the sewing data.
* When memory switch no. 400 is set to ON, the X-scale, Y-scale, sewing speed and work clamp height can be
recorded separately for each program number.
[X/Y-scale and X/Y-offset screen]
(5)
(1) X/Y-scale
(X-Scale, Y-Scale)
(2) Offset
(X-Offset, Y-Offset)
(3) OK key
(4) Default key
(5) Cancel key
(6) Setting key
* When the foot switch is depressed to the 2nd step, home position detection is carried out.
(If using a two-pedal foot switch, lower the work clamp before depressing the start switch. For the hand start switch,
use the right switch to lower the feed plate lock cylinder and work clamp, and then press the left and right switches at
the same time.)
(1)
(4)
Limited by available sewing area.
Setting range: 0 to 400%, 0.1% units, initial value: 100%
When activating the offset, first carry out home position detection(*).
Setting range: 0 to 300 mm, 0.05 mm units
Initial value: 0 mm
Touch to confirm the setting and return the display to the previous screen.
Touch to return the setting to the initial value.
Touch to return to the previous screen without changing the setting.
Touch to display the screen for setting the center point for scaling and the display units
(% or mm).