5.20 Communication function

5.20.1 Communication function

5.20.2 Setting/checking of communication function

Display
Communication mode
Serial protocol
Communication specification
RS-485 terminal
Slave address
Communication
speed
Slave address
Communication
speed
BCC
Data length
Parity check
Stop bit length
Response delay time
Communication range
Contact input signal 1
Contact input signal 1 type
Contact input signal 1 Delay
timer (time delay) of reading
Contact input signal 1 OFF
detection timer
Contact input signal 2
Contact input signal 2 type
Contact input signal 2 Delay
timer (time delay) of reading
Contact input signal 2 OFF
detection timer
Contact
function
Contact
operation
Contact
selected alarm
Contact
function
Contact
operation
Contact
selected alarm
Contact
function
Contact
operation
Contact
selected alarm
1: The default setting when CO02 is PRO1 or PRO2.
2: The default setting when CO15 is SW-A or SW-B.
3: The default setting when CO19 is SW-A or SW-B.
HRS090 Series
Contact input/output and serial communication can be performed.
Refer to the Operation Manual Communication Function for more details
The table below shows the set items of the communication function and
default settings.
Table 5.20-1 Set items of communication function
Item
Sets communication mode.
Sets serial communication protocol.
Sets standard of the serial communication.
Sets of the terminal of RS-485.
Sets slave address.
Sets communication speed.
Sets slave address.
Sets communication speed.
Sets error detection code.
Sets data length.
Sets parity check.
Sets stop bit length
Sets time to delay the response message.
Sets communication range.
Sets contact input signal 1.
Sets input type of contact input signal 1.
Sets the delay timer of reading of contact
input signal 1.
Sets the contact input signal 1 OFF
detection timer
Sets contact input signal 2.
Sets input type of contact input signal 2.
Sets the delay timer of reading of contact
input signal 2.
Sets the contact input signal 2 OFF
detection timer
output
signal
1
Sets contact output signal 1.
output
signal
1
Sets input type of contact output signal 1.
output
signal
1
Sets alarm which is selected for contact
output 1.
output
signal
2
Sets output signal function of contact output
2.
output
signal
2
Sets output signal operation of contact
output 2.
output
signal
2
Sets alarm which is selected for contact
output 2.
output
signal
3
Sets output signal function of contact output
3.
output
signal
3
Sets output signal operation of contact
output 3.
output
signal
3
Sets alarm which is selected for contact
output 3.
Chapter 5
Display and setting of various functions
Contents
4: The default setting when CO23 is A.SEL.
5: The default setting when CO26 is A.SEL.
6: The default setting when CO29 is A.SEL.
HRX-OM- T002
Default setting
LOC
MDBS
485
OFF
1 (----)1
19.2 (----)1
---- (1)1
---- (9.6)1
---- (ON)1
---- (8BIT)1
---- (NON)1
---- (2BIT)1
---- (0)1
---- (RW)1
RUN
ALT
---- (0)2
---- (0)2
OFF
ALT
---- (0)3
---- (0)3
RUN
A
---- (AL.01)4
RMT
A
---- (AL.01)5
ALM
B
---- (AL.01)6
5.20Communication function