Specifications
Ceiling Suspended Type
Model
1 Cooling Capacity (19.5°CWB)
2 Cooling Capacity (19.0°CWB)
3 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Rows×Stages×Fin Pitch
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output × Number
of Units
Fan
Air Flow Rate (H/L)
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Piping
Gas Pipes
Connections
Drain Pipe
Machine Weight (Mass)
5 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Standard Accessories
Drawing No.
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m, level
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m, level
3 Indoor temp. : 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length; 7.5m, level difference;
4 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
5 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
24
FXHQ32MAVE
RT
1.1
kcal/h
3,200
Btu/h
12,600
kW
3.7
kW
3.6
RT
1.1
kcal/h
3,400
Btu/h
13,600
kW
4.0
White (10Y9/0.5)
mm
195×960×680
mm
2×12×1.75
0.182
3D12K1AA1
Sirocco Fan
W
62×1
m³/min
12/10
cfm
424/353
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Wool
Resin Net (with Mold Resistant)
φ
mm
6.4 (Flare Connection)
φ
mm
12.7 (Flare Connection)
VP20
mm
(External Dia. 26 Internal Dia. 20)
kg
24
dBA
36/31
Fuse,
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A P Series
Operation Manual, Installation
Manual, Paper Pattern for Installation,
Drain Hose, Clamp Metal, Insulation
for Fitting, Clamps, Washers.
difference: 0m.
difference: 0m.
0m. (Heat pump only)
these values are normally somewhat higher as a result of ambient conditions.
FXHQ63MAVE
2.1
6,300
24,900
7.3
7.1
2.3
6,900
27,300
8.0
White (10Y9/0.5)
195×1,160×680
3×12×1.75
0.233
4D12K1AA1
Sirocco Fan
62×1
17.5/14
618/494
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Wool
Resin Net (with Mold Resistant)
φ
9.5 (Flare Connection)
φ
15.9 (Flare Connection)
VP20
(External Dia. 26 Internal Dia. 20)
28
39/34
Fuse,
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A P Series
Operation Manual, Installation
Manual, Paper Pattern for Installation,
Drain Hose, Clamp Metal, Insulation
for Fitting, Clamps, Washers.
C: 3D038815A
SiME34-608
FXHQ100MAVE
3.3
10,000
39,600
11.6
11.2
3.6
10,800
42,700
12.5
White (10Y9/0.5)
195×1,400×680
3×12×1.75
0.293
3D12K2AA1
Sirocco Fan
130×1
25/19.5
883/688
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Wool
Resin Net (with Mold Resistant)
φ
9.5 (Flare Connection)
φ
15.9 (Flare Connection)
VP20
(External Dia. 26 Internal Dia. 20)
33
45/37
Fuse,
Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A P Series
Operation Manual, Installation
Manual, Paper Pattern for Installation,
Drain Hose, Clamp Metal, Insulation
for Fitting, Clamps, Washers.
Conversion Formulae