First Alert FA168CPS / FA168CPSSIAA168CPSSIAA168CPSSIAA168CPSSIAFA148CP / FA148CPSIAFA148CP / FA148CPSIA Installation And Setup Manual page 95

Table of Contents

Advertisement

BATTERY FUSE
24-HR BATTERY STANDBY REQUIRED FOR
FOR REPLACEMENT,
FIRE INSTALLATIONS. USE 12V, 17.2AH
3A
USE SAME VALUE
BATTERY FOR 600mA AUX POWER. SEE
(e.g. ADEMCO No. 90-12)
INSTRUCTIONS.
BATTERY CAPACITY FOR EMERGENCY
BURGLARY STANDBY USE AT LEAST 4 HRS
CHARGING VOLTAGE
BLACK
BATTERY
+
13.8VDC. MAXIMUM
FLYING LEADS
12V, 4AH
CHARGING CURRENT
RED
FOR BATTERY
650mA.
+
CONNECTION
SEALED LEAD-ACID TYPE.
BATTERY NORMALLY NEED NOT BE
REPLACED FOR AT LEAST 3 YRS.
RED JUMPER
CUT FOR BELL SUPERVISION.
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY , ADD 100mA TO TOTAL OF
ALSO, CONNECT 2000 OHM
AUX. POWER OUTPUT AND REMOTE
RESISTOR DIRECTLY ACROSS
KEYPAD CURRENTS.
SOUNDER.
USE UL LISTED LIMITED ENERGY
CABLE FOR ALL CONNECTIONS
1
2
CLASS 2 PLUG-IN TRANSFORMER
16.5VAC, 25VA
(e.g. 1321).
(USE No. 1321CN IN CANADA)
USE 1361X10 TRANSFORMER
INTERFACE IN PLACE OF 1321 OR
1321CN WHEN POWER LINE CARRIER
DEVICES ARE BEING USED. (SEE
INSTRUCTIONS FOR CONNECTIONS)
TO 110VAC
UNSWITCHED
THIS EQUIPMENT SHOULD BE INSTALLED
I N A C C O R D A N C E W I T H T H E N AT I O N A L
OUTLET (24HR)
F I R E
P R O T E C T I O N A S S O C I AT I O N ' S
S TA N D A R D 7 2 , C H A P T E R 2 ( N AT I O N A L
+
F I R E P R O T E C T I O N A S S O C I AT I O N ,
B AT T E RY- M A R C H
PA R K ,
Q U I N C Y, M A
ALARM OUTPUT
0 2 2 6 9 ) .
10.5–13.8VDC, 2A MAX.
P R I N T E D
I N F O R M AT I O N
(600mA MAX. FOR UL
D E S C R I B I N G
P R O P E R
I N S TA L L AT I O N ,
USAGE, INCLUDING
O P E R AT I O N , TESTING, MAINTENANCE,
AUX POWER) STEADY
EVACUATION PLANNING AND REPAIR
SERVICE IS TO BE PROVIDED WITH THIS
FOR BURGLARY/PANIC,
EQUIPMENT .
TEMPORAL PULSE
SOUNDING FOR FIRE.
CONNECTION OF THE FIRE ALARM
CAN USE 702 SIREN,
SIGNAL TO A FIRE ALARM
OR 12V BELL).
HEADQUARTERS OR A CENTRAL STATION
SEE INSTRUCTIONS.
SHALL BE PERMITTED ONLY WITH THE
PERMISSION OF THE LOCAL AUTHORITY
HAVING JURISDICTION. THE BURGLAR
ALARM SIGNAL SHALL NOT BE
CONNECTED TO A POLICE EMERGENCY
NUMBER.
8-PIN CONNECTOR
USED FOR 1361X10
TRANSFORMER
CONNECTIONS AND FOR
ON-BOARD TRIGGERS
SEE INSTRUCTIONS.
(USE SA4120XM-1
1 2 3 4
5 6
7 8
CABLE)
SYNC
COM
TO
TRANS.
DATA
TO TERM 4
BLK
TO TERM 5
RED
TO TERM 6
GRN
TO TERM 7
YEL
3
4
5
6
7
8
+
AUX. POWER
OUTPUT
10.5-13.8VDC
600mA MAX.
(500mA MAX.
FOR UL
INSTALLATIONS)
ALL OUTPUTS
ARE POWER
LIMITED.
2000
NOTE:
OHMS
KEYPAD (S)
EOLR
CURRENT (IN
BOTH
REMOTE
PARTITIONS)
KEYPADS
12
AND ALL
AND OTHER
OTHER DEVICES
ADDRESSABLE
DRAWING
DEVICES
POWER FROM
(e.g. 5800TM,
2k
TERMS 4 & 5
4285/4286, LRR,
MUST BE
4219, 4229,
INCLUDED IN
4204, 5881)
AUX CURRENT
REMOTE KEYPADS
2k
DRAIN
CAN USE FA215KP, FA260KP,
CALCULATIONS.
FA260RF, OR FA560KP
KEYPADS. LOCAL
PROGRAMMING MUST BE
ZONE 3
DONE WITH A FA560KP,
DOUBLE BALANCED ZONE
BUT NEED NOT REMAIN IN
THE SYSTEM
(SET TO ADDRESS 16).
FA168CPS / FA168CPSSIA / FA148CP / FA148CPSIA
SUMMARY OF CONNECTIONS
4219
WIRED EXPANSION MODULE
(8 ADD'L EOLR WIRED ZONES)
SET UNIT'S
-OR-
DIP SWITCH
4229
FOR DEVICE
WIRED EXPANSION/RELAY MODULE
ADDRESSES
BLK
(8 ADD'L EOLR WIRED ZONES PLUS 2
7 - 15
RED
OUTPUT RELAYS)
SEE
-OR-
GRN
INSTRUCTIONS.
4204 RELAY MODULE
YEL
(4 OUTPUT RELAYS)
AND/OR
SET
5881* Type
RECEIVER'S
RF RECEIVER
DIP SWITCH
BLK
FOR DEVICE
WIRELESS ZONES
ADDRESS
RED
5881L:
UP TO 8
OF "0".
5881M: UP TO 16
GRN
SEE
5881H: UP TO 64
YEL
INSTRUCTIONS.
*5882 IN CANADA
9
10
12
13
14
15
16
11
2000
2000
2000
2000
OHMS
OHMS
OHMS
OHMS
EOLR
EOLR
EOLR
EOLR
MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)
• RESPONSE, ZONES 1-8: 10, 350, OR 700 MSEC (PROGRAMMABLE)
13
14
MAXIMUM NUMBER OF 2-WIRE SMOKE DETECTORS ON ZONE 1 IS 16;
DETECTORS MUST HAVE COMPATIBILITY IDENTIFIER AS "A".
ZONE
TAMPER
2k
CONTACTS
PAIRS
10
11
2 / 10
3 / 11
4 / 12
ZONE 2
5 / 13
TAMPER
2k
6 / 14
CONTACTS
3k
7 / 15
8 / 16
ZONE 10
2k
2k
6.2k
ZONE 4
TYPICAL WIRING FOR
TYPICAL WIRING FOR
ZONE DOUBLING
(FA168CPS ONLY)
(FA168CPS ONLY)
4-WIRE SMOKE DETECTOR CONNECTIONS
+
5
RELAY
AUX PWR
PROGRAM RELAY
OUTPUT
BLK
AS ZONE TYPE 54
TERMINALS
(FIRE ZONE RESET)
_
4
N.C.
OR
CONTACT OPENS MOMENTARILY
UPON FIRE ALARM RESET
TO OUTPUT 17
+
PROGRAM OUTPUT 17 FOR
_
"OUT NORM LOW" = YES IN
4-WIRE SMOKE
79 MENU MODE AND AS ZONE
OR COMBUSTION
TYPE 54 IN
80 MENU MODE
DETECTOR
MAX. CURRENT = 100 mA
(UP TO 16 DETECTORS
PLUS EOL MODULE)
+
TO ZONE TERM. ( )
HEAT
DETECTOR
_
TO ZONE TERM. ( )
17
18
19
20
21
22
23
TIP
RING
TIP
(BROWN)
(GRAY)
(GREEN)
HANDSET
INCOMING
PHONE LINE
TELEPHONE WIRING
(VIA RJ31X* JACK AND DIRECT
CONNECT CORD)
*CA38A IN CANADA
DOC LOAD NO.: 3
FOR CONNECTION OF OPTIONAL FA4285 OR FA4286 VIP
MODULES TO PHONE TERMINALS, SEE INSTRUCTIONS.
2000
2000
2000
OHMS
OHMS
OHMS
WARNING:
TO PREVENT RISK OF SHOCK,
EOLR
EOLR
EOLR
DISCONNECT TELEPHONE LINE AT TELCO
JACK BEFORE SERVICING THIS UNIT.
COMPLIES WITH FCC RULES, PART 68.
FCC REGISTRATION NO. 5GBUSA-44003-AL-E
RINGER EQUIVALENCE: 0.1B.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
POWER SHUTDOWN NOTE:
OPERATION IS SUBJECT TO THE FOLLOWING TWO
SYSTEM SHUTS DOWN SENSOR
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
DETECTION PROCESSING IF
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
CONTROL'S VOLTAGE DROPS
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
BELOW 9.6V.
THAT MAY CAUSE UNDESIRED OPERATION.
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS
SYSTEM. IN ADDITION, THIS SYSTEM MUST BE CHECKED BY A QUALIFIED
TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.
ALL DEVICES AND ACCESSORIES
USED IN A CANADIAN INSTALLATION
MUST BE LISTED FOR USE IN CANADA
_
+
RED
EOL
POWER
N.O.
SUPERVISION
RELAY MODULE
A77-716B.
USE N.O.
CONTACT,
VIOLET
WHICH CLOSES
WHEN POWER
IS APPLIED.
2000
OHMS
EOLR
24
25
RING
(RED)
EARTH
GROUND
SEE
INSTRUCTIONS
FOR PROPER
GROUNDING
FA168CPS148CP-SOC-V4