FIELD
TITLE and DATA ENTRIES
Pager 2 Characters
*164
Enter up to 16 characters
Pager 2 Report Options
*165
see pager 1 reports, field *162 for entries,
except use zone list 10.
Pager 3 Phone No.
*166
Enter up to 20 digits
Pager 3 Characters
*167
Enter up to 16 characters
Pager 3 Report Options
*168
see pager 1 reports, field *162 for entries,
except use zone list 11.
Pager 4 Phone No.
*169
Enter up to 20 digits
Pager 4 Characters
*170
Enter up to 16 characters
Pager 4 Report Options
*171
see pager 1 reports, field *162 for entries,
except use zone list 12.
Pager Delay Option for Alarms
*172
0 = none
1 = 1 minute

Miscellaneous System Fields

Clean Me Option
*174
0 = disable
1 = enable
Device Duration 1, 2
*177
0 = 15 secs
1 = 30 secs
2 = 45 secs
3 = 60 secs
4 = 90 secs
5 = 2 min
50/60 Hz AC Operation
*181
0 = 60 Hz
1 = 50 Hz
2 = 2 minutes
3 = 3 minutes
6 = 2-1/2 min #+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
EXPLANATION
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗164∗.
Enter the types of reports to be sent to pager 2 for each partition.
FA168CPS.
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number. To clear entries from this field, press ∗166∗.
FA168CPS.
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗167∗.
FA168CPS.
Enter the types of reports to be sent to pager 3 for each partition.
FA168CPS.
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number. To clear entries from this field, press ∗169∗.
FA168CPS.
See field ∗161 for explanation of entries. If fewer than 16 characters,
exit by pressing [∗] and next field number. To clear entries from this
field, press ∗170∗.
FA168CPS.
Enter the types of reports to be sent to pager 4 for each partition.
This field determines the delay of alarm reports to the pager. This
gives the Central Station enough time to verify the alarm report that
it received, before the dialer attempts to dial the pager.
This delay is for ALL pagers in the system.
This is a maintenance feature for ESL 2-wire smoke detectors
on Zone 1. If used, this option limits the number of smoke detectors to
a maximum of 10, rather than 16. To enable the "clean me" feature, a
time response setting of "3" (1.2 seconds) must be entered in ∗56 Zone
Programming for zone 1.
These entries set the duration for output action options 5 (duration
1) and 6 (duration 2) programmed in ∗80 Output Function
Programming.
Select the type of AC power applied to the control.
This option is used for Real-Time Clock synchronization.
4-11