Various System Trouble Displays - First Alert FA168CPS / FA168CPSSIAA168CPSSIAA168CPSSIAA168CPSSIAFA148CP / FA148CPSIAFA148CP / FA148CPSIA Installation And Setup Manual

Table of Contents

Advertisement

Installation Instructions

Various System Trouble Displays

Alpha Display
ALARM CANCELED
EXIT ALARM
CHECK
ALARM 1xx
FAULT 1xx
CHECK 1xx
SYSTEM LO BAT
LO BAT
TELCO FAULT
Busy-Standby
Modem Comm
no display
Comm. Failure
Open Circuit
Long Rng Trbl
Bell Failure
RCVR Jam
KEYPAD LOW BAT
Phone Okay
Dialer Off
Test in Progress
Upload Completed
Upload Failed
12-4
Fixed Disp. Meaning
CA
will appear if an exit or interior zone contained a fault during closing at the time
the Exit Delay ended (e.g., exit door left open), but the system was disarmed
during the Entry Delay time. The alarm sounder and keypad sound continuously,
but stop when the system is disarmed. No message will be transmitted to the
central station.
EA
will appear when the Exit Delay ends if an exit or interior zone contained a fault
during closing. The alarm sounder and keypad sound continuously until the
system is disarmed (or timeout occurs). An "Exit Alarm" message is sent to the
central station. Also results if an alarm from an exit or interior zone occurs
within 2 minutes after the end of an Exit Delay.
CHECK
indicates that a problem exists with the displayed zone(s) and requires attention.
1xx
indicates that communication between control and a zone expander or wireless
1xx
receiver is interrupted, where "xx" is the device address. Check the wiring and
1xx
DIP switch settings on the units.
91
If field *199 is set to "1," all ECP module problems are displayed as "91."
If there are wireless sensors in the system, the Check condition may also be
caused by some change in the environment that prevents the receiver from
receiving signals from a particular sensor.
BAT
with no zone number indicates that the system's main standby battery is weak.
BAT
with a zone number and a once-per-minute beeping at the keypad indicates that a
low-battery condition exists in the wireless sensor displayed (zone "00" indicates a
wireless keypad). If the battery is not replaced within 30 days, a "CHECK"
display may occur.
NOTE: Some wireless sensors contain a non-replaceable long-life battery which
requires replacement of the entire unit at the end of battery life (e.g., Nos. 5802,
5802CP).
94
Telephone Line Failure, indicates that a monitored telephone line (if programmed
in field *92) has been cut or disconnected. Depending on how the system was
programmed, the keypad may also produce a trouble sound, and the external
sounder may be activated. Silence by entering installer code + OFF.
dl
If this remains displayed for more than 1 minute, the system is disabled.
CC
The system is in communication with the central station for change of function or
status verification.
no display
Power Failure
If there is no keypad display at all and the LEDs are unlit, operating power (AC
and battery) for the system has stopped and the system is inoperative.
If the message "AC LOSS" (Alpha display keypads) or "NO AC" (Fixed-Word
display keypads) is displayed, the keypad is operating on battery power only.
If the battery standby capacity is used up during a prolonged AC power outage,
the control's power will shut down to minimize deep discharge of the battery.
FC
A communication failure has occurred.
OC
The keypad is not receiving signals from the control and sees an open circuit.
bF
Backup LRR communication failure.
70
Bell supervision failure.
90
RF jam detected.
00 BAT
Wireless keypad low battery
Cd
The dialer test has been successful (CID code 601).
dO
The dialer is disabled.
dd
Walk test mode is active(CID code 607).
dC
The upload or download session was completed.
dF
The upload or download session failed before completion.