Manrose FAN0531 Instructions

Through roof fan cowls and fan kits

Advertisement

Quick Links

Through Roof Fan Cowls and Fan Kits
Please ensure these instructions are read thoroughly before commencing installation
and that all documentation is left with the home owner on completion of installation
CAUTION
• Before use, please check that the supply voltage and that of the appliance are the same (see product rating label).
• All wiring and wiring connections must comply with national wiring rules and regulations.
• Any changes or modifications made or attempted to this product, without the prior written approval of the manufacturer, will void any and all
stated warranties.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they are capable of, and have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• In case of damage to the supply cord, switch off the device and do not tamper with it. Damaged supply cords must only be repaired or
replaced exclusively by the manufacturer or by an appointed representative. Failure to comply with the above may endanger the safety of
people and cause possible damage to the whole system.
• Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.
ELECTRICAL CONNECTION
NOTE: Junction box supplied is suitable for internal use and below roof installation
• Cut the Dektite roof flashing on the 150/160 marking and fit to the rigid duct before commencing
(see separate installation sheet detailing this).
• For below roof terminations the motor lead exit hole should be as far down the rigid duct as is practical –
allow enough lead to protrude from the duct as is required for termination. After fitting the Dektite, drill
an 8mm hole at a suitable point in the rigid duct and fit the supplied rubber grommet. The motor lead can
then be passed through the grommet to the outside of the rigid duct.
• The assembly can now be placed in position in the roof penetration (see instructions on page 3). Once the
assembly has been fastened to the roof by the Dektite fastening procedure, the electrical connections can be
made. The junction box can be fastened to the rigid duct if necessary.
Junction box is supplied for the following cowls and kits with an axial EC inline fan:
FAN0531 / FAN0532 / FAN0533 / FAN0534 / FAN0739 / FAN1009 / FAN1060 / DCT0189
Junction box is supplied for the following cowls and kits with a centrifugal inline fan:
FAN0529 / FAN0530 / FAN0535 / FAN0740 / FAN0967 / FAN1002
• You may find it more convenient to pull the whole assembly down as far as possible in the Dektite flashing
to carry out the terminations (Fig 1). Once completed, the assembly can then be pushed back up through the
Dektite. Ensure that a visual check is made above the roof afterwards to check that the Dektite is sealing
correctly around the rigid duct (Fig 2). Once the terminations are completed the rigid duct can then be
fastened to a rafter or purlin with the supplied clamp for rigidity. Ducting connections can then be made.
• Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other
fuel-burning appliances.
TECHNICAL
Installation Instructions
info@ventair.com.au | www.manrose.com.au
Max.
Duct
Fan Type
Fan Watts
(mm)
(W)
150
Centrifugal
70
150
Axial
18
Specifications are subject to change without notice
(inside the building)
Free Air Fan
Max.
Performance
Fan Pressure
(Pa)
(l/s)
(m
/hr)
3
320
153
550
91
105
380
Fig 1
Fig 2
Specific
Sound
Fan Power
Switching
dB(A)
(W/l/s)
0.46
62
Standard
0.17
38
Standard
Distributed by Ventair Pty Ltd
Page 1

Advertisement

loading

Summary of Contents for Manrose FAN0531

  • Page 1 Junction box is supplied for the following cowls and kits with an axial EC inline fan: FAN0531 / FAN0532 / FAN0533 / FAN0534 / FAN0739 / FAN1009 / FAN1060 / DCT0189 Junction box is supplied for the following cowls and kits with a centrifugal inline fan: FAN0529 / FAN0530 / FAN0535 / FAN0740 / FAN0967 / FAN1002 •...
  • Page 2 50 l/s Metres of Ducting Metres of Ducting No. of No. of Bends Bends Fan Selection Hyper150 EC Mixflo 150 Blue Jet Installation Instructions Page 2 Specifications are subject to change without notice info@ventair.com.au | www.manrose.com.au Distributed by Ventair Pty Ltd...
  • Page 3 Through Roof Fan Cowls and Fan Kits WIRING CONNECTIONS For axial EC inline fan models (no capacitor): For centrifugal (3 speed) inline fan models: FAN0531 / FAN0532 / FAN0533 / FAN0534 FAN0967 FAN0739 / FAN1009 / FAN1060 / DCT0189 White (3)
  • Page 4 Please use the FAN2444 fan timer model shown Do not use old model FAN2444 (with resistor) or FAN0372 fan timers Installation Instructions Page 4 Specifications are subject to change without notice info@ventair.com.au | www.manrose.com.au Distributed by Ventair Pty Ltd PUB1545 2001...