Table 4-10 Model Number - Prodigit 3110 Series Operation Manual

Plug-in electronic load
Table of Contents

Advertisement

76 PRODIGIT
4.6.3. SYSTEM Set and Read the Status of 3110
[SYStem : ] RECall{ SP }m{ ,n }
Syntax : [ SYStem : ] RECall{ SP }m{ ,n }{;NL}
Purpose : Recall the status of Loading which had been saved in the Memory
Description: This command is for recalling the status of Load which had been saved
In the Memory .
m(STATE)=1~10,n(BANK)=1~15.
If the operating module is other series, omit "n" and it will be operated in the BANK
Which has been shown on the display.
For Example
RECALL 2,15 → Recall the status of Loading which had been saved in the 2nd and
15th BANK of the memory
REC 3 → Recall the status of loading which had been saved in the 3rd of
Memory. If 3110 is operated, it will be operated in the BANK which has been shown
on the display.
[SYStem: ] STORe{SP}m{,n}
Syntax : [SYStem : ] STORe{SP}m{,n}{;NL}
Purpose:Save the status of Loading to the Memory
Description:This command is for saving the status of Loading to the Memory.
m(STATE)=1~10,n(BANK)=1~15 .
If 3110 is operated, omit "n" and it will be operated in the BANK which has been shown
on the display
For Example
STORE 2,15  Save the status of Loading which had been saved in the 2nd and 15th
BANK of memory.
STOR 3  Save the status of Loading to the 3rd memory. If it is operated with 3110,
BANK will be set the BANK which shows on the display.
[SYStem : ] NAME?
Syntax : [SYStem : ] NAME?{;NL}
Purpose : Read the model number of Load
Description: This command is for reading the model number of Load. it will be lit the
model number as table 4-10 :
BANK(n)
STATE(m)
TOTAL STATE
MODEL
3110
3111
3114
3117
3119

Table 4-10 MODEL NUMBER

3110
15
10
150

Advertisement

Table of Contents
loading

This manual is also suitable for:

31103111311431173119

Table of Contents