44 PRODIGIT
3.2.23. V-sense input terminal
The V-sense terminals can be used to compensate for a voltage drop in the load
lines between the power supply and the 3110 series Electronic Load. This is a
useful feature useful when the load current is relatively high.
If remote sense is required the V-sense terminals are connected to the appropriate
positive and negative terminals of the power supply as shown in Fig 3-2.
In the CONFIG menu the V-sense function can be set to AUTO or ON.
Please note that if V-sense is set to AUTO and the sense leads are connected to
the DUT the losses need to be approx. 1V (3110, 3111,3117 ) or 6V (3114 & 3119)
before the display compensates for the voltage loss.
If V-sense is set to 'ON' and the sense terminals are connected to the DUT the load
will check and compensate for all voltage drops.
The maximum voltage sense compensation is the same as the rating of the 3110
series electronic load module. For example the 3110 is capable of sinking current at
up to 80Vdc. Therefore the maximum V-sense is also 80Vdc.

Fig 3-2 typical connection of 3110 series load module