The data collected on the J2K with Multi Media Card will open in a spreadsheet with the recorded on
calculated values displayed in the following format.
Column
Description
A
Date DD.MM.YYYY
B

Time HH:MM:SS

C
O2 in vol.%
D
CO in ppm
E
NO in ppm
F
NO2 in ppm
G
SO2 in ppm
H
CO w/ O2 correction applied
I
NO w/ O2 correction applied
J
NO2 w/ O2 correction applied
K
NOX w/ O2 correction applied
L
SO2 w/ O2 correction applied
M
T.Gas in °C or °F
N
T.Air in °C or °F
O
Draft in " H2O
P
CO2 in vol.%
Q
Efficiency in %
R
Losses in %
S
Excess air (Lambda)
T
Dew point in °C or °F
U
Poisoning index
V
O2 (gas channel check) in vol.%
W
CO (gas channel check) in ppm
X
CO (gas channel check) in ppm
Y
O2 (check if O2 mixed) in vol.%
Z
T. Boiler
AA
T. Sensor (internal sensor temp) 0 – 99 F
AB
O2 Correction
AC
Unit of measure
AD
O2 Correction
AE
Fuel type number
AF
Fuel type text
AG
Soot Test # 1 value
AH
Soot Test # 2 value
AI
Soot Test # 3 value
AJ
Oil trace
Range/Comment/Example
13:02:2006 (February 13, 2006)
09:36:54 (9:36:54 AM)
0.0 – 21.0
0 - 4000
0 – 4000 Standard, 0.0 – 300.0 Low NOx
0 – 500 Standard, 0.0-50.0 Low NOx
0 – 5000 (0 if SO2 sensor not installed)
0.0-20.0 %
0.0-20.0 %
0.0-20.0 %
0.0-20.0 %
0.0-20.0 % (0 if SO2 sensor not installed)
Exhaust Gas temperature w/ probe
Ambient Air temperature at instrument
0.0 – 40.0 inches water gage
0.0 – 25.0
0.0 – 100.0
0.0 – 100.0
1.00 = 0.00% excess air, 1.20 = 20% excess air
0.0 – 21.0
related to 0,0 vol.% O2
Measured value
0.0 – 21.0
0 - 999
0.0 – 21.0 (programmed by user)
0=ppm; 1=mg/m3; 2=mg/kWh; 3=mg/MJ
N= O2 correction value.
Refer to instrument fuel choices
Refer to instrument fuel choices
0.0 – 9.9
0.0 – 9.9
0.0 – 9.9
0=no; 1=yes;