5. Disassamble the iPump
disassemble the ipump
Armafl ex insulation
hose clamp
common supply pipe
Armafl ex insulation
30
return line
electrical heater
Installation instructions iPump A 2-7, 3-11
All hydraulic lines are insulated with Ar-
mafl ex. If it is necessary to remove the In-
sulation in case of disassabling the iPump,
the insulation must be restored correctly
after assembly.
The hose clamp of the return line under the hot water
tank can be untighten with a screw driver and can
be pulled down. After this the return line can be dis-
connected from the hot water tank. The hose clamp
is under the Armafl ex insulation. To open the hose
clamp, the insulation must be pulled down.
The bolting of the common supply pipe for heating
and domestic hot water preparation can be loosened
with a pipe wrench. The bolting is located in the front
of the iPump, on the right side under the electrical
pan.
Under the bolting, the immersion heater is placed.
The fl ow pipe is insulated with Armafl ex. To reach the
bolting without diffi culty, the Armafl ex insulation must
be opened. The insulation must be restored correctly
after assembly.
When opening the fi ttings, please ensure
that no electrical cables are not beeing
damaged.