3 . 7. Te ch n ical d at a
Heat pump type
Model
Space heating water energy effi ciency class
Energy effi ciency class water heating
Performance data acc. to EN 14511 at nominal speed
Heat output at A2°C/W35°C
Power consumption at A2°C/W35°C
COP at A2°C/W35°C
Cooling capacity at A35°C/W18°C
Power consumption at A35°C/W18°C
EER at A35°C/W18°C
Sound emission
1
Sound power level nominal according to EN 12102 indoor unit
Sound power level maximum according to EN 12102 indoor unit
Sound power level nominal according to EN 12102 outdoor unit
Sound power level maximum according to EN 12102 outdoor unit
Sound reduced operation outdoor unit (reduced power)
The sound pressure level can be calculated with
the iDM-sound calculation tool
Dimensions indoor unit
Height / Width / Depth
Tilted height
Weight
Minimum size of installation room
Dimensions outdoor unit
Height / Width / Depth
Weight
Hot water tank
Volume of hot water storage tank
Maximum storage temperature
Maximum storage temperature with electrical heating unit
Max. single draw of hot water at 46°C tapping temp. - Heat pump
Max. single draw of hot water at 46°C tapping temp. - Electrical heater
Max. single draw of hot water at 40°C tapping temp. - Heat pump
Max. single draw of hot water at 40°C tapping temp. - Electrical heater
Max. operating pressure heating side
Max. operating pressure domestic hot water
Hot water connection
Cold water connection
(C) IDM ENERGIESYSTEME GMBH
(with standard fi lling)
2
Installation instructions iPump A 2-7, 3-11
iPump A 2-7 iPump A 3-11
230 V
A
+++
-
35°C 55°C 35°C 55°C
-
A
Unit
kW
3.90
kW
0.88
-
4.42
kW
4.95
kW
1.03
-
4.80
dB(A)
42
dB(A)
52
dB(A)
46
dB(A)
49
dB(A)
46
mm
1950 / 600 / 786
mm
2150
kg
251
7.27
mm
1180 / 1110 / 745
kg
110
l
°C
°C
l
3
l
4
3
l
l
4
bar
bar
R
R
description
400 V
230 V
+++
A
A
+++
A
++
A
5.92
1.35
4.37
7.80
1.81
4.32
45
48
50
53
49
2150
270
9.32
113
192
55
75
260
356
315
432
3
10
3/4"
3/4"