Top Vent Adapter Installation; Rear Vent & Rear Vent To Top Vent Adapter Installation; Thermostat Installation And Operation - Quadra-Fire SANTA FE SANTAFE-C Installation Manual

Pellet appliance
Table of Contents

Advertisement

SANTA FE FREESTANDING
B. Top Vent Adapter Installation
3 to 3 inch Top Vent Adapter
3 to 6 inch Top Vent Offset Adapter
Installing the Top Vent Adapter
1. Put a layer of high temperature silicone on the 3 inch
(76mm) exhaust outlet. Do not put silicone inside of
pipe (Figure 21.1).
2. Slide the top vent adapter onto the rear exhaust
outlet and adjust the assembly to a vertical position
(Figure 21.1).
3. Drill 4 holes with #26 drill bit (provided) into the back of
the appliance using the outer shield as a pattern (make
sure the assembly is vertical) (Figure 21.2).
4. Install the 4 mounting screws.
5. Drill 2 holes with #26 drill bit through the rear exhaust
outlet using the 2 holes already in the short horizontal
pipe in the top vent adapter as a guide. Install the 2
screws (Figure 21.1).
6. Install the vent pipe into the top vent adapter.
7. To clean the top vent adapter open the clean-out cover
(Figure 21.2).
Offset Adapter
(812-3570)
Vent Adapter
(TPVNT-2)
Use Hole on Each
Side as Drilling Guide
Figure 21.1
Figure 21.2
21
Silicone Rear
Exhaust Outlet
Drill Holes in back of
appliance and secure with 4
screws, 2 on each side
Clean-Out Cover
C. Rear Vent & Rear Vent to Top Vent Adapter
Installation
1. Put a layer of high temperature silicone on the 3 inch
(76mm) exhaust outlet. Do not put silicone inside of
pipe (Figure 21.1).
2. Slide the adapter onto the rear exhaust outlet and
adjust the assembly to the appropriate position.
3. Install the vent pipe into the adapter.
Figure 21.3 - Rear Vent Adapter
Figure 21.4 - Rear to Top Vent Adapter - 90°
D. Thermostat Installation and Operation
The kit comes with a programmable wall thermostat and
25' of thermostat wire. If you need to run more than 25'
make sure you use a continuous strand of 18 to 22 gauge
thermostat wire. For optimum performance your thermostat
should be:
Mounted on an inside wall, approximately 5' above
the floor
Do not locate where there is poor air circulation such
as in a corner, alcove, behind doors, bookcase or
other objects
Located away from drafts, direct sunlight, above a
lamp, television, radiator, a wall next to a window, or
direct heat from the appliance
Avoid damp environments as this can lead to corrosion
that may shorten thermostat life
If painting or construction work around, cover the
thermostat completely or wait until work is complete
before installation.
Shock hazard.
Do NOT remove grounding prong
from plug.
Plug directly into properly grounded three
prong receptacle.
Route cord away from appliance.
Do NOT route cord under or in front
of appliance.
7050-801E
Rear Vent
Adapter
(811-0620)
Clean-Out Cover
Top Vent
Adapter
(TPVNT-6)
Clean-Out
Cover
CAUTION
09/20