1.
0.5
0.25
Futura Book 24Pt
LUXOMAT
Operating and mounting instructions for motion detector LUXOMAT
1. Mounting preparations
1
2
1) Caution: have all work involving the 230 V
mains supply carried out by a qualified
electrician! Before starting disconnect the
mains! Please be aware, that the LUXOMAT
RC-plus next is not suitable as an intrusion
detector, since it is not equipped with a
tamper contact.
2) Socket base corner mounting
3) In the case of mounting over the previous
socket "RC-plus" use the extra cover that is
provided.
3
5. Putting into operation / Settings
5
Self test cycle
After mounting and connecting the 230 VAC supply
voltage, the LED flashed for 1min. to show a self testing
unit. Then the unit is ready for operation and the set-
tings can be made manually or with remote control
(see point 11).
1
2
1) Remove the coverring with slightly pressure
2) Adjust Range, follow-up accommodation and Lux value with screwdriver
7. Sensor head optics
7
10°
180°
1
45°
1) Change range or sensitivity adjustments
by swivelling of the sensor head vertically
or horizontally (Sensor head horizontally =
max. range)
2) Fine adjustment of sensor axis
10
10. Mounting place
1
1) If possible mount unit on a safe place
(wall or ceiling mount).
®
2. Mounting types
2
®
1) Wall mounting
2) Ceiling mounting
3) Outside corner mountable with plug-in
socket (included with the RC-plus next 280,
see point 20)
+
1
4
15s 30s
1,5 2 3 5 6 7 10
8. Sensitivity adjustment (mounting height 2.50 m);
8
2
mounting height min. = 2.00 m
(Sensor head justified horizontally, see point 7)
130°
3
1
2
1) Range walking across: approx. 21m
2) Range walking towards: approx. 7 - 8 m
3) Anti-creep: approx. 1 - 3 m
2
2) Influence of weather reduces the lifetime of
the unit. Please take care to mount correctly.
RC-plus next
3. Plug-in socket
3
1
1
2
10°
3
3
1) Press here for separation of terminal case
and plug-in socket
2) Mount the plug-in socket with two screws
and the enclosed seal rings on a firm base
(Pay attention to inserting of the connection
cable, see point 4)
3) Imprint the terminal case on plug-in socket.
The terminal case on the plug-in socket is
rotatable upto 10° for fine adjustment of the
motion detector.
-
Mechanical range adjustment
+: e.g. 21m, –: e.g. 5m (mounting height 2.50 m)
mounting height min. = 2.00 m
(RC-plus next 130: 1 zone; RC-plus next 230:
1:4
2 zones; RC-plus next 280: 3 zones, see point 8)
1.
Follow-up time
0.5
Test operation, 15 sec. ... 16 min., Pulse operation
8
16
0.25
(Test operation: range testing, detector switches
on/off the lighting at any recognized movement)
Futura Book 24Pt
Lux value
12
Night operation...Dusk...Day operation
(Day operation: light sensor inactive, switching at
any brightness value)
LED Functional display
3m
Display of movements and operating states
(Switchable with remote control LUXOMAT
see point 11)
230°
15s 30s
1,5 2 3 5 6 7 10
3m
1m
8m
3m
21m
Mechanical range adjustment possible
max
min
1m
for every zone separately (see point 5)
8m
21m
3m
1m
8m
21m
4
3) Minimum distance to switched lighting,
frontally or laterally to device: 1m
4) Never mount the connected lights below the
motion detector!
RC-plus next
®
4. Inserting of the connection cable
4
4
1 :
1 .
5
0 .
2 5
0 .
P t
2 4
o k
o
B
r a
t u
F u
2
1) Connection cable from top down
2) Connection cable from below
3) Connection cable from behind
4) Terminal markings
(Wiring diagrams see point 17)
6. Factory settings
6
3m
1m
On delivery the potentiometers are adjusted in
position "TEST" and "SUN" symbol (daytime
operation). With this adjustments the following
8m
regular values are active:
21m
Follow-up accommodation: 3 min.
Lux value: approx. 20 Lux
Reset: The adjusting into "Factory settings" from
1m
any other position causes a "Reset" of the device.
1
4
8
16
That means all parameters are resetted into factory
1m
settings (fast LED-flashing).
8m
IR-RC,
®
21m
8m
3m
1m
21m
9. Exclude sources of interference
9
8m
21m
280°
1m
8m
21m
1m
1
4
1 :
8m
1 .
5
0 .
21m
1) Push in cover-up clips on marked place
2 5
0 .
P t
2 4
o k
o
B
r a
t u
F u
(blind out distant range/close-up range/
both)
2) Cover-up stickers
11. Settings of remote control
11
3
1
> 1m
1) LUXOMAT
2) LUXOMAT
point 20)
Caution: Settings with remote control subscribe
the settings by courtesy of potentiometers (see
point 5 ) (for description see point 12).
GB
1
2
3
4
&
"TEST"
12
2
2
IR-RC (accessory, see point 20)
®
IR-RC-Mini (accessory, see
®
Need help?
Do you have a question about the RC-plus next 130 and is the answer not in the manual?
Questions and answers