Genie Z-45/22 Service Manual page 63

Hide thumbs Also See for Z-45/22:
Table of Contents

Advertisement

Service Manual - First Edition
D-6
Clean PCV Hoses and Fittings -
Gasoline/LPG Models
Maintaining PCV hoses is essential to good engine
performance. Improperly functioning PCV hoses
will fail to ventilate the crankcase and continued
use of neglected hoses could result in component
damage.
Perform this procedure with the
engine off.
1 Remove the 3 bolts from the engine pivot plate.
Swing the engine pivot plate away from
machine to access the PCV hoses.
a
a
pivot plate bolt
2 Disconnect the 2 hoses from the PCV valve,
then disconnect the 2 hoses from the engine.
Part No. 29487
Section 4 - Scheduled Maintenance Procedures
c
Gasoline/LPG models
(shown with distributor cap removed)
a
PCV valve
b
hose, PCV valve to carburetor
c
hose, PCV valve to crankcase
3 Clean the hoses with a mild cleaning solvent.
4 Dry both hoses and inspect them for cracks
and damage. Replace the hoses if they are
damaged.
a
a
Genie Z-45/22
TABLE D PROCEDURES
a
b
4 - 37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents