MODE 009
Factory setting bit : 0 0 0 1 1 0 1 0 (Hex : 1A)
Bit
Feature
765
Select default display of
communication mode.
43210
MODE 011
Factory setting bit : 0 0 1 1 0 0 0 0 (Hex : 30)
Bit
Feature
76
Select dial line speed
(DP speed).
(PSTN2)
5
Switch PB/DP. (PSTN2)
4
Extension / External line
connection.
(PSTN2)
3210
Logic
Meaning
000
G3-1
*
011
G3-2
Others
Not available
11010
Fixed to "11010"
Logic
Meaning
00
10 pps
01
20 pps
*
10
16 pps
11
Not available
0
DP
*
1
PB
0
Extension
connection
*
1
External line
connection
0000
Fixed to "0000"
S-41
Description
Specifies what to display at
first as communication
mode.
Returns "Communication
mode" to its default after
each operation.
This soft switch is
unavailable in some
systems:
• With single port (includ-
ing pseudo-multi port)
G3 type: all are unavailable
• With multi port
PSTN+PSTN:
G3-1, G3-2 available
Description
• This is valid only when
"Switch PB/DP (MODE
011 Bit5)" sets DP.
• 16pps is unavailable to
users.
Select a line type (tone or
pulse) for calling.
• DP : pulse
• PB : tone
Select standard phone line
connected with the system

Advertisement